Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Jun 20, 2026

Contrast Enhanced Vessel Imaging using MicroCT
05:50

Contrast Enhanced Vessel Imaging using MicroCT

Published on: January 27, 2011

Vascular imaging in small rodents using micro-CT.

Sebastian J Schambach1, Simona Bag, Christoph Groden

  • 1Department of Neuroradiology, University of Heidelberg, Mannheim, Germany.

Methods (San Diego, Calif.)
|September 24, 2009
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Accelerated Deep-Learning-Based Image Reconstruction for 3D T2 Dark-Fluid in Imaging of Multiple Sclerosis.

Investigative radiology·2026
Same author

Correction: Association of sarcopenia with survival and treatment response in brain metastasis of non-small cell lung cancer.

Scientific reports·2026
Same author

Impact of Deep-Learning Reconstruction on MRI Workflows: A Retrospective Analysis at a Large Academic Tertiary Center.

RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin·2026
Same author

Clinicopsychological stratification of recovery outcomes in cerebral aneurysm patients following cluster analysis.

PNAS nexus·2026
Same author

Relevance of a complete re-resection of contrast enhancing tumor in MGMT promotor non-methylated versus methylated recurrent glioblastomas.

Brain & spine·2026
Same author

Real-time planar angiographic cerebral perfusion imaging.

International journal of computer assisted radiology and surgery·2026
Same journal

An accessible, absorbance-based plate reader assay to assess cumulative exposure of blood plasma & serum to thawed conditions.

Methods (San Diego, Calif.)·2026
Same journal

EC-isHCR: A rapid method for in situ hybridization chain reaction in diverse animal samples.

Methods (San Diego, Calif.)·2026
Same journal

Single-Molecule methods to investigate mechanisms of transcription by RNA polymerase of Mycobacterium tuberculosis.

Methods (San Diego, Calif.)·2026
Same journal

Detection and sequencing of Usutu virus during mosquito surveillance: Use of multiple assays and techniques for identification at low levels.

Methods (San Diego, Calif.)·2026
Same journal

Experimental validation of an AI-driven digital healthcare platform for oral health behavior and plaque assessment among vietnamese children.

Methods (San Diego, Calif.)·2026
Same journal

Zeta potential: An efficient and cost-effective alternative for investigating cell-surface interactions.

Methods (San Diego, Calif.)·2026
See all related articles

This article outlines a high-speed, high-resolution imaging technique for visualizing blood vessels in mice using specialized X-ray scanning technology. By comparing different contrast agents, the authors provide a practical guide for researchers to capture detailed anatomical images of vascular structures in under one minute.

Area of Science:

  • Vascular imaging research within micro-computed tomography angiography diagnostics
  • Small animal models in preclinical cardiovascular medicine

Background:

No prior work had fully resolved the logistical hurdles of achieving rapid, high-resolution vascular visualization in small murine subjects. Researchers often struggle to balance the need for speed with the requirement for fine anatomical detail in living models. That uncertainty drove the development of improved imaging protocols for studying diseases like strokes or tumors. It was already known that traditional methods frequently failed to capture both structural and functional data efficiently. This gap motivated the exploration of advanced scanning configurations to enhance diagnostic capabilities. Prior research has shown that existing tools often lack the necessary precision for tiny vessel networks. Scientists require reliable techniques to monitor changes in vessel diameter during experimental disease progression. The current landscape demands a standardized approach to overcome these persistent technical limitations in preclinical imaging.

Purpose Of The Study:

Keywords:
preclinical imagingmurine modelscontrast agentsX-ray scanning

Frequently Asked Questions

The researchers propose a dual-method approach using either a bolus injection of conventional contrast or a blood-pool agent. This allows for flexible visualization of vascular anatomy depending on whether the goal is transient flow dynamics or stable vessel structure assessment.

The authors utilize micro-computed tomography angiography, a specialized X-ray technique. This tool is necessary for achieving the high spatial and temporal resolution required to resolve tiny vessels in mice, which conventional scanners often miss.

A high degree of precision is required because murine vessels are extremely small and subject to motion artifacts. The authors note that the scanning setup must be carefully calibrated to maintain isotropic resolution at sixteen micrometers.

The authors use blood-pool contrast agents to maintain signal stability throughout the scan. This data type is vital for accurately mapping the complex, branching networks of the circulatory system without the rapid washout seen in standard bolus injections.

More Related Videos

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
11:09

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals

Published on: December 16, 2022

Quantitative Micro-CT Analysis of Aortopathy in a Mouse Model of β-aminopropionitrile-induced Aortic Aneurysm and Dissection
06:46

Quantitative Micro-CT Analysis of Aortopathy in a Mouse Model of β-aminopropionitrile-induced Aortic Aneurysm and Dissection

Published on: July 16, 2018

Related Experiment Videos

Last Updated: Jun 20, 2026

Contrast Enhanced Vessel Imaging using MicroCT
05:50

Contrast Enhanced Vessel Imaging using MicroCT

Published on: January 27, 2011

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
11:09

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals

Published on: December 16, 2022

Quantitative Micro-CT Analysis of Aortopathy in a Mouse Model of β-aminopropionitrile-induced Aortic Aneurysm and Dissection
06:46

Quantitative Micro-CT Analysis of Aortopathy in a Mouse Model of β-aminopropionitrile-induced Aortic Aneurysm and Dissection

Published on: July 16, 2018

The aim of this work is to establish a fast, user-friendly imaging protocol for visualizing vascular structures in small rodents. Researchers frequently encounter difficulties when attempting to capture high-resolution data in living mice. This study addresses the need for a tool that simultaneously records anatomical structure and biological function. The authors seek to overcome the technical barriers associated with tiny vessel imaging. By refining the scanning setup, they intend to improve the accuracy of preclinical disease modeling. This effort is motivated by the requirement for precise measurements in studies of strokes and neoplasms. The team explores how different contrast agents influence the quality of the resulting vascular maps. They provide a comprehensive guide to facilitate the adoption of these techniques in other laboratories.

Main Methods:

Review approach involves evaluating a specialized scanning configuration for small rodents. The authors detail a protocol utilizing both bolus and blood-pool contrast agents. This design focuses on optimizing spatial and temporal resolution for murine subjects. The team implemented a system capable of achieving isotropic resolution at sixteen micrometers. Scanning durations were strictly limited to under one minute to ensure animal safety. The methodology addresses common technical difficulties encountered during the visualization of tiny vessel networks. Researchers followed a standardized sequence to ensure reproducibility across different experimental models. This systematic approach provides a clear guide for implementing the described imaging setup.

Main Results:

Key findings from the literature indicate that the described setup achieves isotropic resolutions of sixteen micrometers. The authors report that total scanning times remain consistently below one minute. This efficiency allows for high-throughput imaging of vascular structures in living mice. The data show that both bolus and blood-pool contrast agents provide sufficient detail for anatomical analysis. The researchers successfully captured complex vessel anatomy in models of neoplasm and stroke. Their results confirm that the protocol overcomes previous limitations regarding speed and image clarity. The study highlights the successful application of this technique in small animal subjects. These findings establish a reliable benchmark for future preclinical vascular investigations.

Conclusions:

The authors demonstrate that their specific scanning configuration achieves isotropic resolutions reaching sixteen micrometers. This protocol effectively minimizes total scan duration to less than sixty seconds per subject. Synthesis and implications suggest that this approach improves the feasibility of longitudinal studies in small animal models. The researchers propose that using blood-pool contrast agents offers distinct advantages for capturing stable vascular anatomy. Their findings indicate that both bolus and blood-pool techniques are viable for different experimental objectives. This work confirms that high-precision imaging is attainable despite the inherent challenges of tiny murine physiology. The team emphasizes that their methodology provides a robust framework for future preclinical investigations. These results provide a clear pathway for standardizing vascular assessment across various disease models.

The researchers measure the isotropic resolution, which reaches sixteen micrometers. This phenomenon allows for the visualization of fine vessel diameters that are otherwise invisible in standard preclinical imaging setups.

The authors claim that this protocol facilitates faster, more accessible imaging for studies involving strokes or neoplasms. They suggest that reducing scan times to under one minute minimizes anesthesia exposure for the animals.