Related Experiment Video
Updated: Jun 20, 2026

Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
Baroreflex sensitivity of an arterial wall during rotary blood pump assistance
Tomoyuki Yambe1, Kou Imachi, Yasuyuki Shiraishi
1Department of Medical Engineering and Cardiology, Institute of Development, Aging and Cancer, Tohoku University, Tohoku, Japan. yambe@idac.tohoku.ac.jp
Abstract:
It is well known that the baroreflex system is one of the most important indicators of the pathophysiology in hypertensive patients. We can check the sensitivity of the baroreflex by observing heart rate (HR) responses; however, there is no simple diagnostic method to measure the arterial behavior in the baroreflex system. Presently, we report the development of a method and associated hardware that enables the diagnosis of baroreflex sensitivity by measuring the responses of both the heart and the artery. In this system, the measurements are obtained by monitoring an electrocardiogram and a pulse wave recorded from the radial artery or fingertip. The arterial responses were measured in terms of the pulse wave velocity (PWV) calculated from the pulse wave transmission time (PTT) from the heart to the artery. In this system, the HR change corresponding to the blood pressure change in time series sequence was observed. Slope of the changes in blood pressure and HR indicated the sensitivity of the baroreflex system of the heart. This system could also measure the sensitivity of the baroreflex system of an artery. Changes in the PWV in response to the blood pressure changes were observed. Significant correlation was observed in the time sequence between blood pressure change and PWV change after calculating the delay time by cross-correlation. The slope of these parameter changes was easily obtained and it demonstrated the sensitivity of the baroreflex system of an artery. We evaluated this method in animal experiments using rotary blood pump (RBP) with undulation pump ventricular assist device, and PTT elongation was observed in response to increased blood pressure with RBP assistance. Furthermore, when tested clinically, decreased sensitivity of the baroreflex system in hypertensive patients was observed. This system may be useful when we consider the ideal treatment and follow-up of patients with hypertension.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...

