Related Concept Videos

Radiation Pressure: Problem Solving01:09

Radiation Pressure: Problem Solving

The radiation pressure applied by an electromagnetic wave on a perfectly absorbing surface equals the energy density of the wave. The wave's momentum also gets transferred to the surface when an electromagnetic wave is entirely absorbed by it. The rate at which momentum is transmitted to an absorbing surface perpendicular to the propagation direction equals the force on the surface.
The average value of the rate of momentum transfer divided by the absorbing area represents the average force per...
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
Dual Nature of Electromagnetic (EM) Radiation01:10

Dual Nature of Electromagnetic (EM) Radiation

Electromagnetic (EM) radiation consists of electric and magnetic field components oscillating in planes perpendicular to each other and mutually perpendicular to radiation propagation through space. EM radiation can be classified as a wave, characterized by the properties of waves such as wavelength (denoted as λ) and frequency (represented by ν).
Wavelength is the distance between two consecutive peaks (the highest point) or troughs (the lowest point) in the wave. Frequency is the number of...
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
Atomic Emission Spectroscopy: Overview01:20

Atomic Emission Spectroscopy: Overview

Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...