Related Experiment Video
Updated: Jun 19, 2026

Pediatric Animal Model of Extracorporeal Cardiopulmonary Resuscitation After Prolonged Circulatory Arrest
Published on: May 26, 2023
Effect of a miniaturized cardiopulmonary bypass system on the inflammatory response and cardiac function in neonatal
Ko Yoshizumi1, Kozo Ishino, Shinya Ugaki
1Department of Cardiovascular Surgery, Okayama University, Graduate School of Medicine and Dentistry, Okayama, Japan. k-yoshi@med.m.kanazawa-u.ac.jp
Abstract:
The cognitive impairment and hemodynamic instability after neonatal cardiac surgery with cardiopulmonary bypass (CPB) might be exacerbated by hemodilution. Therefore, this study investigated the impact of different bloodless prime volumes on the hemodynamics and the inflammatory response by a miniaturized CPB system in neonatal piglets. The bypass circuit consisted of a Capiox RX05 (Capiox Baby RX, Terumo Corp., Tokyo, Japan) oxygenator and 3/16 internal diameter arterial and venous polyvinyl chloride tubing lines, with a minimum 75 mL prime volume. Twelve 1-week-old piglets were placed on a mild hypothermic CPB (32 degrees C) at 120 mL/kg/min for 2 h. The animals were divided into two groups, based on the volume of the prime solution. The priming volume was 75 mL in Group I and 175 mL in Group II. No blood transfusions were performed, and no inotropic or vasoactive drugs were used. The interleukin-6 (IL-6) and thrombin-antithrombin (TAT) complex levels, as well as right ventricular and pulmonary functions, were measured before and after CPB. Group I had low levels of IL-6 and TAT immediately after CPB (4370 +/- 2346 vs. 9058 +/- 2307 pg/mL, P < 0.01 and 9.9 +/- 7.7 vs. 25.1 +/- 8.8 ng/mL, P < 0.01, respectively). Group I had significantly improved cardiopulmonary function, cardiac index (0.22 +/- 0.03 vs. 0.11 +/- 0.05 L/kg/min, P < 0.001), and pulmonary vascular resistance index (7366 +/- 2860 vs. 28 620 +/- 15 552 dynes/cm(5)/kg, P < 0.01) compared with Group II. The miniaturized bloodless prime circuit for neonatal CPB demonstrated that the influence of hemodilution can reduce the subsequent inflammatory response. In addition, a low prime volume could therefore be particularly effective for attenuating pulmonary vascular resistance and right ventricular dysfunction in neonates.
More Related Videos
09:54A Recovery Cardiopulmonary Bypass Model Without Transfusion or Inotropic Agents in Rats
Published on: March 23, 2018
10:55A Piglet Perinatal Asphyxia Model to Study Cardiac Injury and Hemodynamics after Cardiac Arrest, Resuscitation, and the Return of Spontaneous Circulation
Published on: January 13, 2023