Inter-rater reliability of manual QT measurement and prediction of abnormal QT,HR pairs
Related Experiment Video
Updated: Jun 19, 2026

Examining Changes in HRV and Emotion Following Artmaking with Three Different Art Materials
Published on: January 11, 2020
Geoffrey K Isbister1, Leonie Calver, Freek Van Gorp
1Department of Clinical Toxicology and Pharmacology, Calvary Mater Newcastle Hospital, Waratah, NSW, Australia. geoffrey.isbister@ menzies.edu.au
Objectives:
To assess interobserver agreement when trained healthcare staff measure the QT interval using a standardized approach across a range of QT lengths.
Methods:
A sample of 110 electrocardiograms (ECGs) was taken from general and psychotropic overdose admissions to the emergency department including drugs known to cause QT prolongation and Torsades de Pointes. Four of the authors measured the QT interval in all ECGs using a previously developed approach. Each rater was blinded to the ECG admission details and the measurements of the other raters. The primary outcome was the inter-rater agreement for the median QT and interobserver classification as to whether the QT interval was abnormal or not, based on the QT nomogram.
Results:
There was good agreement between raters (intraclass correlation coefficient, 0.61; 95% CI = 0.53 to 0.69). When classifying the QT as abnormal there was good agreement between the raters with a Fleiss' kappa of 0.61. There was perfect agreement between all four raters on 86 of 110 ECGs (78.2%), agreement between three raters on 18 of 110 (16.3%), and a split between the four on 6 of 110 (5.5%). Disagreement between the automated QT measurement and the majority of the raters was slightly more than within raters.
Conclusions:
The study demonstrates that there is good agreement between trained observers when manually measuring the QT interval using a standardized approach. This provides an inexpensive method for the measurement of QT in clinical studies of drug overdose and a potentially useful approach in the clinical assessment of patients with possible QT prolongation.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
08:12Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Quartile
1; 1; 2; 2; 4; 6; 6.8; 7.2; 8; 8.3; 9; 10; 10; 11.5
The median or second quartile is seven. The lower half of the...