Related Experiment Video
Updated: Jun 19, 2026

Characterization, Quantification and Compound-specific Isotopic Analysis of Pyrogenic Carbon Using Benzene Polycarboxylic Acids (BPCA)
Published on: May 16, 2016
Evaluation of polycyclic aromatic hydrocarbons in asphalt binder using matrix solid-phase dispersion and gas
Paulo R N Fernandes1, Sandra de A Soares, Ronaldo F Nascimento
1Laboratório de Polímeros, Departamento de Química Orgânica e Inorgânica, Universidade Federal do Ceará, bloco 940. Av. Humberto Monte, s/n-Campus do Pici. CEP: 60455-760-Fortaleza, CE, Brasil.
Abstract:
A method developed for the extraction and analysis of polycyclic aromatic hydrocarbons (PAHs) in the asphalt binder using a matrix solid-phase dispersion (MSPD) and gas chromatography is presented. The MSPD method was proposed as a rapid and easy approach to determining PAHs present in the maltenic phase of asphalt binder extracted through a mechanical shaking and sonication of the material. The recovery rates ranged from 62.77-89.92% (shaking) and from 56.54-93.6% (sonication) with relative standard deviations lower than 8.8%. The study shows that the recovery rates using shaking and sonication extractions are not significantly different at the p < 0.05 level. The limits of detection and quantification ranged from 0.7-1.8 mg/kg and 2.2-5.6 mg/kg, respectively. The proposed analytical method was applied to determine PAH levels in an asphalt binder from Brazil. The main PAHs found were BbF, BaP, Per, IncdP, DahA, and BghiP, with average concentrations of 10.2-20.7 mg/kg, but the PAHs Ace and Acy were not detected. However, Nap, Fl, Phen, Ant, Flr, Pyr, Chry, BaA, and BkF were present in average concentrations amounting to less than 10 mg/kg. The results showed that the MSPD method is potentially a valuable tool for the determination of PAHs in the asphalt binder.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Aromatic Compounds: Overview
In 1825, Faraday isolated benzene...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...

