Related Experiment Video
Updated: Feb 17, 2026

Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
Rapid simultaneous quantitative determination of different small pharmaceutical drugs using a conventional
Markus Persike1, Michael Karas
1Cluster of Excellence Macromolecular Complexes, Institute of Pharmaceutical Chemistry, Goethe University Frankfurt, Max-von-Laue-Str. 9, 60438 Frankfurt, Germany. persike@iachem.de
Abstract:
The present study establishes a simple, rapid and sensitive method for the simultaneous quantification of different small pharmaceutical drugs using a matrix-assisted laser desorption/ionization source (MALDI) coupled with a time-of-flight (TOF) mass analyzer. Neither time-consuming sample preparation, nor special target plates, isotopically labelled internal standards or other extra equipment are necessary. A simple standard dried-droplet preparation with the common matrix alpha-cyano-4-hydroxycinnamic acid (CHCA) was used. The background signals of CHCA in the low-mass region did not pose the presumed problem, because the sensitivity, resolution and mass accuracy of a modern MALDI-TOF MS system is sufficient to overcome this difficulty. Four experiments were performed in order to verify the quantification method. First, ten different phenothiazines were quantified in the range of 5-2000 nM (1-880 ng/mL). A good precision (relative standard deviation (RSD) 4.4-9.3%), linearity (R2 >0.99) and accuracy (error 4.7-11%) was obtained in all cases. Additionally, simultaneous quantification of these ten phenothiazines was carried out in human plasma without prior chromatographic separation in the range of 2-1750 ng/mL yielding good linearity, precision and accuracy (mean RSD 7.6%; R2 >0.99, mean error 8.0%). Accordingly, a quantitative analysis of ten chemically and pharmaceutically unrelated drugs was performed in the same way. A comparable linearity (R2 >0.99), precision (mean RSD 7.6%) and accuracy (mean error 8.3%) was obtained in the range of 5-2000 nM. Finally, the prazosin content of a commercial tablet was directly determined without further purification steps.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
Related Concept Videos
MALDI-TOF Mass Spectrometry
Matrix-Assisted Laser Desorption Ionization (MALDI)
Tandem Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Analyzers: Common Types