Identification of hemodynamically unstable arrhythmias using subcutaneous photoplethysmography
Robert G Turcott1, Todd J Pavek
1Division of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, California 94305-5406, USA. turcott@stanford.edu
Introduction:
Determination of hemodynamic status is central to arrhythmia management in the inpatient setting. In contrast, therapy decisions in implantable cardioverter defibrillators (ICDs) are based exclusively on the arrhythmia's electrical signature. Hemodynamic sensing in ICDs would allow tailoring of therapy according to perfusion status. Subcutaneous photoplethysmography (PPG) is an attractive technology for this application because it responds to changes in arterial pressure and can be readily incorporated into the housing of implanted devices. This study evaluated the accuracy of PPG in identifying hemodynamically unstable simulated arrhythmias in an animal model.
Methods And Results:
Rapid atrial and ventricular pacing was used to simulate arrhythmias in an acute preparation of 7 healthy dogs. Aortic pressure and subcutaneous PPG were simultaneously recorded. Simulated arrhythmias were defined as hemodynamically unstable if aortic pressure decreased by >or=15 mmHg, marginally unstable if pressure decreased by 5-15 mmHg, and hemodynamically stable if pressure either increased or decreased by no more than 5 mmHg. An average of 56 arrhythmias were simulated in each animal. Changes in pressure and PPG output were highly correlated, with correlation coefficient of 0.7-0.9. Subcutaneous PPG identified hemodynamically unstable episodes with a sensitivity of 100% for 6 subjects and 80% for 1 subject. Specificity was more than 90% for 6 subjects and was 50% for 1 subject.
Conclusions:
Subcutaneous PPG detects hemodynamically unstable simulated arrhythmias in an acute canine preparation. If successfully validated in humans, this technology may allow ICD therapy to be specifically tailored according to the hemodynamic status of the arrhythmia.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Dysrhythmias V: Evaluating Dysrhythmias
Dysrhythmias III: Characteristics of Dysrhythmias
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...