Related Experiment Video
Updated: Jun 19, 2026

3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
Published on: October 24, 2019
Intrarenal artery delineation with ultra high resolution, flat panel based, volume computerized tomography: outer
Martin Neukamm1, Moritz Palmowski, Soenke Bartling
1Department of Diagnostic and Interventional Radiology, University of Heidelberg, Heidelberg, Germany.
Purpose:
New methods of noninvasive high resolution imaging may improve the delineation of tumor microvessels and, thus, be of significant help in surgical planning and cost-effective monitoring of novel anti-angiogenic therapy. We determined the maximum delineation of intrarenal microvessels with a novel flat panel based volume computerized tomography system in an experimental setting.
Materials And Methods:
We prospectively evaluated 13 porcine renal specimens for intrarenal vessel delineation using a prototype gantry based, flat panel, cone beam computerized tomography system. The gantry incorporates an array of a 40 x 30 cm(2) CsI amorphous silicon flat panel detector consisting of a 2,048 x 1,536 matrix. After catheterizing the renal artery with a 5Fr end hole catheter a contrast enhanced scan was performed using BaS as contrast medium at a dilution of 200 mg/ml. The diameter of all definable arterial branches was determined using a software tool based on Medical Imaging and Interaction Toolkit, allowing semi-automatic segmentation of the vessel tree. In step 1 the vessel tree is segmented by a 3-dimensional region growing algorithm. Following its medial axis the vessel tree is extracted and converted to a representation, including the diameter of the vessels.
Results:
In each kidney an average +/- SD of 47,454 +/- 22,382 arterial branches could be delineated. The diameter of the branches was 0.029 (mean 0.032 +/- 0.0025) to 3.444 mm (mean 1.813 +/- 0.6139) with a median of 0.263 mm. Of visible intrarenal arteries 2.7% had a vessel diameter of 0.029 mm.
Conclusions:
Flat panel based volume computerized tomography can visualize intrarenal microvessels down to a diameter of 0.03 mm. It may improve the assessment of renal microvessel architecture in healthy patients and in those with pathological conditions.
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Imaging Studies III: Computed Tomography
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

