Fetal Mouse Cardiovascular Imaging Using a High-frequency Ultrasound (30/45MHZ) System
Published on: May 5, 2018
[Teratogenic risk of low level ionizing radiation. Congenital heart disease in infant]
Monica Cresci1, Ilenia Foffa, Lamia Ait-Ali
1Unità di Ricerca Genetica, Istituto di Fisiologia Clinica, Consiglio Nazionale delle Ricerche, Pisa.
Insights
Maternal exposure to ionizing radiation during early pregnancy may increase the risk of congenital heart defects in infants. This case study highlights a potential link between occupational radiation exposure and birth defects.
Area of Science:
- Cardiology
- Medical Physics
- Teratology
Background:
- Congenital heart diseases (CHDs) are the most common and lethal birth defects globally.
- CHDs arise from complex interactions between genetic and environmental factors.
- Prenatal risk factors, including occupational exposures, are increasingly studied.
Observation:
- A case report of a 4-month-old infant with a congenital heart defect.
- The infant's mother worked in a cardiovascular catheterization laboratory.
- Maternal exposure occurred during the first 4 weeks of pregnancy.
Findings:
- The mother's radiation dose was 4220 microSieverts (µSv).
- This dose is equivalent to approximately 210 chest X-rays.
- The findings suggest a potential teratogenic effect of ionizing radiation.
Implications:
- This case raises concerns about occupational radiation safety for pregnant healthcare workers.
- Further research is needed to establish a causal link between low-dose radiation and CHDs.
- Protecting pregnant workers from radiation is crucial for preventing birth defects.
Abstract:
Congenital heart diseases--the most prevalent and fatal birth defects worldwide--result from a combination of genetic predisposition and environmental factors. Currently, there is a growing body of epidemiological literature on parental and occupational prenatal risk factors. We report a case of a 4-months-old infant whose mother was professionally exposed to the cardiovascular catheterization laboratory during the first 4 weeks of pregnancy. The total radiation dose recorded by dosimeters under apron was 4220 microSiviert equivalent to 210 chest X-rays, suggesting the hypothesis of maternal ionising radiation induced-teratogenic effect.
Related Concept Videos
Teratogenicity
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Mitral Stenosis I: Introduction
Biological Effects of Radiation
The Periodic Table and Organismal Elements
Periodic Table Provides Information...
Drug Toxicity: Risk factors