Related Experiment Video
Updated: Jun 18, 2026

Implantation Surgery for Abdominal Vagus Nerve Stimulation and Recording Studies in Awake Rats
Published on: January 19, 2024
Clinical phase I/feasibility study of the next generation indwelling Provox voice prosthesis (Provox Vega)
Frans J M Hilgers1, Annemieke H Ackerstaff, Maya van Rossum
1Department of Head and Neck Oncology and Surgery, The Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, Amsterdam, The Netherlands. f.hilgers@nki.nl
Conclusions:
Provox Vega prostheses demonstrate good short-term feasibility, and their optimized airflow-resistance design offers laryngectomy patients indwelling voice prostheses with more choices in outer diameters without sacrificing (too) much in voice quality.
Objectives:
Technological progress enables improvement of in vitro airflow characteristics of voice prostheses and design of voice prostheses with smaller outer diameters. This could potentially improve voice quality in users of Provox2, and avoid diminished voice quality in users of prostheses with smaller outer diameters.
Methods:
This was a prospective clinical phase I/feasibility study of three newly designed indwelling voice prostheses (Provox Vega 22.5 (Provox2 successor), 20, and 17Fr). Assessments consisted of patients' self-reported voice and speech, perceptual evaluation, acoustic analysis, maximum phonation time, loudness, speech rate, pull-out force and adaptation of the tracheoesophageal (TE) puncture to smaller diameter voice prostheses. Vega 22.5 was assessed in 15 patients (all Provox ActiValve users, observation period 3 weeks), and 16 patients with Vega 20/17 (2 weeks each).
Results:
No voice prostheses problems were encountered. Half of the patients with Vega 22.5 preferred that for its better voice quality. Voice and speech were considered equal to Provox2 for Vega 20, but slightly less for Vega 17. Most TE punctures adapted well to the smaller diameter voice prostheses.
Related Concept Videos
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask and...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Esophageal Achalasia