Related Experiment Video
Updated: Jun 18, 2026

Non-invasive Assessments of Subjective and Objective Recovery Characteristics Following an Exhaustive Jump Protocol
Published on: June 8, 2017
Is performance of intermittent intense exercise enhanced by use of a commercial palm cooling device?
Thomas B Walker1, Michael F Zupan, Julia N McGregor
1Air Force Research Laboratory, Brooks City-Base, Texas, USA. Thomas.walker@brooks.af.mil
Abstract:
The purpose of this study was to determine if using the CoreControl Rapid Thermal Exchange (RTX), a commercial palm cooling device, during active rest periods of multiple set training is an effective means to increase performance. Ten volunteers (5 men, 5 women) completed a VO2max test on a motorized treadmill and 3 interval running tests on a human powered treadmill. This treadmill allowed the subjects to quickly reach their running speed while allowing for measurement of distance, speed, and force. During the interval running tests the subjects completed eight 30-second intervals at a hard/fast pace followed by a 90-second walking or light jogging recovery period. During the recovery period, the subjects placed their left hand on 1 of 3 media: the RTX held at 15 degrees C (R), a 15 degrees C standard refrigerant gel pack (P), or nothing at all (C). Although there were differences in core temperature (Tc), subjective heat stress ratings, distance, and power generated between intervals, there were no significant differences (p < 0.05) found between treatments for any of these variables, nor was the interaction effect of interval*treatment found to be significant. Mean distance completed per trial was 717.1 m +/- 124.4 m (R), 724.8 m +/- 130.3 m (P), and 728.6 m +/- 110.6 m (C). Change in Tc from baseline to end-test averaged 1.41 degrees C +/- 0.37 degrees C (R), 1.41 degrees C +/- 0.39 degrees C (P), and 1.41 degrees C +/- 0.59 degrees C (C). There were no significant differences (p < 0.05) in Tc, heart rate (HR), or VO2 between intervals or treatments. We conclude that the RTX, in its current iteration, is ineffective at improving performance and/or mitigating thermal stress during high-intensity intermittent exercise.
More Related Videos
Related Concept Videos
Responses to Heat and Cold Stress
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Thermal Stress
Thermoregulation
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...

