Optical coherence tomography quantitative analysis of iris volume changes after pharmacologic mydriasis
Florent Aptel1, Philippe Denis
1Department of Ophthalmology, Edouard Herriot Hospital, Lyon 1 University, Lyon, France.
Ophthalmology
|November 20, 2009
Summary
Anterior segment optical coherence tomography (AS OCT) can estimate iris volume. Pharmacologic mydriasis increases iris volume in narrow-angle eyes, narrowing the angle despite laser iridotomy.
Area of Science:
- Ophthalmology
- Medical Imaging
- Anatomy
Background:
- Iris volume changes are critical in angle-closure glaucoma.
- Pharmacologic mydriasis is commonly used in ophthalmologic examinations.
- Understanding iris dynamics is essential for managing narrow-angle eyes.
Purpose of the Study:
- To introduce a method for iris volume estimation using anterior segment optical coherence tomography (AS OCT).
- To quantify iris volume changes induced by pharmacologic mydriasis.
- To compare these changes in narrow-angle eyes versus normal open-angle eyes.
Main Methods:
- A cross-sectional study involving 30 narrow-angle eyes and 30 normal open-angle eyes.
- Iris volume was measured using AS OCT before and after pupil dilation with tropicamide and phenylephrine.
- Key outcome measures included iris volume, pupil diameter, and angle configuration (AOD 500, TISA 500).
Main Results:
- Iris volume increased significantly in narrow-angle eyes after mydriasis (P<0.01) but decreased in open-angle eyes (P<0.01).
- Predictors of iris volume increase included predisposition to angle-closure, larger pupil diameter, and brown irides.
- Increased iris volume correlated with angle narrowing (decreased AOD 500 and TISA 500) in narrow-angle eyes.
Conclusions:
- AS OCT provides a reliable method for estimating iris volume.
- Pupil dilation causes iris volume to increase in eyes predisposed to angle-closure.
- This iris biometric change contributes to angle narrowing, even with a patent iridotomy.