A new angiographic method to assess coronary flow reserve-validation in humans

Harald Rittger1, Asher Kuper, Ole-Alexander Breithardt

  • 1Medizinische Klinik II, Klinikum Coburg gGmbH, Coburg, Germany. rittger@arcor.de

Insights

A new method estimates coronary flow reserve (CFR) using coronary angiograms, avoiding invasive procedures. This angiogram-based CFR measurement correlates well with Doppler-derived CFR, offering a comparable alternative for assessing coronary circulation.

Area of Science:

  • Cardiology
  • Medical Imaging
  • Hemodynamics

Background:

  • Coronary flow reserve (CFR) assesses coronary circulation integrity.
  • Traditional CFR measurement requires invasive intracoronary procedures.
  • A novel algorithm estimates CFR from coronary angiograms non-invasively.

Purpose of the Study:

  • To evaluate a new algorithm for estimating CFR from coronary angiograms.
  • To compare non-invasive CFR measurements with invasive Doppler-derived CFR.
  • To determine the feasibility and accuracy of angiogram-based CFR.

Main Methods:

  • Twenty-seven patients with chest pain underwent cardiac catheterization.
  • Coronary flow reserve was measured using Doppler wire (CFR(doppler)).
  • Coronary angiograms were analyzed using densitometry to calculate CFR(angio).

Main Results:

  • An excellent correlation was observed between CFR(angio) and CFR(doppler) (r=0.87, P<0.0001).
  • The average absolute difference between both methods was 0.36 +/- 0.31.
  • CFR(angio) demonstrated high agreement with CFR(doppler).

Conclusions:

  • Angiogram-based CFR measurement is feasible.
  • This non-invasive method provides results comparable to Doppler-derived CFR.
  • Coronary angiography densitometry offers a viable alternative for CFR assessment.