About estimating the limit of detection of heteroscedastic analytical systems
Elio Desimoni1, Barbara Brunetti
1Dipartimento di Scienze e Tecnologie Alimentari e Microbiologiche, Università degli Studi di Milano, Via Celoria 2, 20133 Milano (I), Italy. elio.desimoni@unimi.it
Abstract:
The limit of detection is a fundamental figure of merit in chemical analysis. Many different approaches are available for its estimation, but only few allow analysing data characterized by a significant change of precision with concentration. Among these, the ISO 11843-2 approach is certainly the most suitable. However, its implementation may not look easy to operators needing to develop the necessary spreadsheets by commercial software packages. This paper is aimed to verifying if alternative approaches are available for getting acceptably approximate estimates of the limit of detection (LOD). Pragmatically, they were set-up by simply adapting some of the approaches already available in the literature, but compatible only with homoscedastic analytical systems. The results obtained by these alternative approaches when analysing a series of calibrations relevant to the electroanalytical determination of hexavalent chromium in some water samples were compared to those furnished by the ISO approach. The results allowed confirming the critical role of the numerosity of the available data on the consistency of any estimate. Even when using the ISO approach, reliable estimates were only obtained by performing a number of calibrations usually uncommon under standard routine conditions. In such a situation, the differences between the results obtained by all the examined approaches appear less important.
Related Concept Videos
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
High-Performance Liquid Chromatography: Types of Detectors
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Detection of Gross Error: The Q Test