Related Experiment Video
Updated: Jun 18, 2026

Preparation and Maintenance of Bioexclusion IsoPositive Cage Experiment for Human Fecal Transplantation into Germ-Free Mice
Published on: February 28, 2025
Humidity and cage and bedding temperatures in unoccupied static mouse caging after steam sterilization
Gina M Ward1, Kelly Cole, Jennifer Faerber
1University Laboratory Animal Resources, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Abstract:
Contemporary rodent caging and equipment often are sterilized by steam autoclaves prior to use in facilities. This work assessed the microenvironment of unoccupied static mouse cages after steam sterilization to determine when internal temperatures had cooled to levels appropriate for rodent housing. Polycarbonate static cages containing food and corncob bedding were stacked (10 rows x 7 columns) in duplicate (front and back; n = 140 cages) on a storage truck and autoclaved to 249 degrees F (121 degrees C). Cages (n = 6) were assessed to represent top, middle, and bottom rows and edges of columns. After cage sterilization, hygrothermometers were placed in cages to measure internal cage temperature (IT), bedding temperature (BT), and cage humidity (CH) every 10 min for 150 min. At time 0, there were no significant differences in averaged temperatures or humidity across cage locations: IT, 95.9 degrees F; BT, 109.8 degrees F; and CH, 84.1%. Over time, significant positional effects occurred. Whereas IT and BT for cages in the center row cooled more slowly than those on the bottom row, CH in top row cages decreased more quickly compared with other cages. After 150 min, the average measures overall were IT, 75.8 degrees F; BT, 77.9 degrees F; and CH, 82.4%. Comparison of the overall measures at 150 min with those of cages cooled overnight (IT, 72.4 degrees F; BT, 71.0 degrees F; and CH, 49%) and cages housing mice (IT, 72.2 degrees F; BT, 70.7 degrees F; and CH, 82%) indicated that a poststerilization cooling period of greater than 2.5 h was necessary to achieve permissible rodent housing conditions at our institution, particularly with corncob bedding autoclaved within the cage.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Temperature