Related Experiment Video
Updated: Jun 18, 2026

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry (UPLC-MS)
Published on: March 14, 2013
Serum steroid profiling for congenital adrenal hyperplasia using liquid chromatography-tandem mass spectrometry
Claudia Rossi1, Lisa Calton, Gareth Hammond
1Centro Studi sull'Invecchiamento (Ce.S.I.), Fondazione Universitaria G. d'Annunzio, Chieti, Italy.
Background:
Diagnosis of Congenital Adrenal Hyperplasia (CAH) is based on the quantification of 17-hydroxyprogesterone (17-OHP), usually by immunoassay. During the neonatal period the specificity of screening for CAH by blood spot 17-OHP immunoassay is low. High false-positive rates result in a relatively high demand for a second-tier serum confirmation test. A robust, specific and selective method for measurement of cortisol, 21-deoxycortisol, 11-deoxycortisol, 4-androstene-3,17-dione (A4) and 17-OHP in serum has been developed. The method involves a simple extraction procedure and a fast analysis using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC/MS/MS).
Methods:
The steroids were extracted from 50microl of serum using methyl-tert-butyl-ether. Analysis was performed on a UPLC tandem quadrupole mass spectrometer system in positive mode electrospray ionization and multiple reaction monitoring acquisition.
Results:
The assay was linear over each analyte concentration range with all correlation coefficients (r(2))>0.996. Inter- and intra-day CVs were
Conclusions:
A second-tier test for the confirmation of CAH has been developed. The method allows for detection and quantification of 5 steroids related to CAH over the range of the clinical assay with good linearity, sensitivity and precision.
More Related Videos
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...