Modification of a commercial cavity ring-down spectroscopy NO2 detector for enhanced sensitivity
Patricia Castellanos1, Winston T Luke, Paul Kelley
1Department of Chemical and Biomolecular Engineering, University of Maryland, College Park, Maryland 20742, USA. patti@umd.edu
Abstract:
Nitrogen dioxide (NO(2)) plays a central role in atmospheric chemistry, air pollution, and biogeochemical cycles. Many analytical techniques have been developed to detect NO(2), but only chemiluminescence-based instruments are commonly, commercially available. There remains a need for a fast, light, and simple method to directly measure NO(2). In this work we describe the modification and characterization of a small, commercially available cavity ring-down spectroscopy (CRDS) NO(2) detector suitable for surface and aircraft monitoring. A metal oxide scrubber was added to remove NO(2), and provide a chemical zero, improving the detection limit (3sigma of the background noise) from several parts per billion by volume (ppbv) to 0.06 ppbv, integrated over 60 s. Known interferences by water and particles were removed using Nafion tubing and a 1 microm Teflon filter, respectively. A 95% response time of 18+/-1 s was observed for a step change in concentration. The CRDS detector was run in parallel to an ozone chemiluminescence device with photolytic conversion of NO(2) to NO. The two instruments measured ambient air in suburban Maryland. A least-squares fit to the comparison data resulted a slope of 0.960+/-0.002 and R of 0.995, showing agreement within experimental uncertainty.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...