Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye
Published on: June 20, 2015
Aqueous humor outflow facility by tonography does not change with body position
Deepan Selvadurai1, David Hodge, Arthur J Sit
1Department of Ophthalmology, Mayo Clinic, Rochester, Minnesota, USA.
Investigative Ophthalmology & Visual Science
|December 5, 2009
Summary
Intraocular pressure (IOP) changes with body position, but aqueous humor outflow facility remains stable. This study found no significant difference in outflow facility between seated and supine positions.
Area of Science:
- Ophthalmology
- Physiology
Background:
- Intraocular pressure (IOP) is known to vary with body position.
- Changes in episcleral venous pressure (EVP) account for most, but not all, of this IOP variation.
- Other aqueous humor dynamic parameters may also influence positional IOP changes.
Purpose of the Study:
- To investigate the variation of aqueous humor outflow facility with changes in body position.
- To determine if body posture affects aqueous humor dynamics beyond IOP.
- To assess the role of outflow facility in positional IOP variations.
Main Methods:
- Healthy volunteers (24-45 years old) underwent constant weight tonography using a modified electronic Schiotz tonometer.
- Measurements were taken in both seated (70 degrees from horizontal) and supine positions, with at least 30 minutes between.
- Tonography data were analyzed using second-order polynomials to determine IOP and outflow facility.
Main Results:
- Forty-two eyes from 21 subjects were analyzed.
- Intraocular pressure (IOP) was significantly higher in the supine position (19.9 +/- 1.6 mm Hg) compared to the seated position (17.8 +/- 1.7 mm Hg) (P < 0.001).
- Mean aqueous humor outflow facility showed no significant difference between the seated (0.30 +/- 0.31 microL/mL/mm Hg) and supine (0.28 +/- 0.09 microL/mL/mm Hg) positions (P = 0.37).
Conclusions:
- Aqueous humor outflow facility, as measured by electronic Schiotz tonography, does not significantly change between supine and sitting body positions.
- The observed positional variations in IOP are likely not mediated by changes in aqueous humor outflow facility.
- Further research may be needed to identify other contributing factors to positional IOP changes.
Related Concept Videos
Open Angle Glaucoma: Treatment
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
Drugs such as carbonic anhydrase inhibitors, α2- and...
Ultrasonography
Ultrasonography is an imaging technique that uses high-frequency sound waves to visualize the body's internal structures. It is a non-invasive and safe procedure that does not involve the use of ionizing radiation, making it widely used in various medical fields. Ultrasonography is used to study heart function, blood flow in the neck or extremities, certain conditions such as gallbladder disease, and fetal growth and development.
During an ultrasonography procedure, a handheld device called a...
During an ultrasonography procedure, a handheld device called a...
Glaucoma: Overview
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
Imaging Studies VI: Voiding Cystourethrography and Cystography
Voiding Cystourethrography (VCUG) and Cystography are specialized radiographic procedures used to examine the structure and function of the bladder and urethra.Voiding Cystourethrography (VCUG)A Voiding Cystourethrogram (VCUG) is a diagnostic imaging procedure that assesses the anatomy and function of the lower urinary tract. It focuses on the bladder, bladder neck, and urethra, helping detect abnormalities such as vesicoureteral reflux (VUR)—the backward or reverse flow of urine into the...
Angle Closure Glaucoma: Treatment
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
Urodynamic Studies: Uroflowmetry
Uroflowmetry is a non-invasive urodynamic test designed to measure various aspects of urination, including volume, flow rate, and the time to void. This test is crucial for diagnosing and assessing conditions such as bladder outlet obstruction, bladder dysfunction, incomplete bladder emptying, incontinence, and urinary tract blockages caused by benign prostatic hyperplasia (BPH) and urethral strictures.Pre-Test Instructions:Before a uroflowmetry test, patients are typically advised to drink...