Magnetic Field Of A Current Loop01:16

Magnetic Field Of A Current Loop

Consider a circular loop with a radius a, that carries a current I. The magnetic field due to the current at an arbitrary point P along the axis of the loop can be calculated using the Biot-Savart law.
Magnetostatic Boundary Conditions01:28

Magnetostatic Boundary Conditions

An electric field suffers a discontinuity at a surface charge. Similarly, a magnetic field is discontinuous at a surface current. The perpendicular component of a magnetic field is continuous across the interface of two magnetic mediums. In contrast, its parallel component, perpendicular to the current, is discontinuous by the amount equal to the product of the vacuum permeability and the surface current. Like the scalar potential in electrostatics, the vector potential is also continuous...
Magnetic Field Due To A Thin Straight Wire01:27

Magnetic Field Due To A Thin Straight Wire

Consider an infinitely long straight wire carrying a current I. The magnetic field at point P at a distance a from the origin can be calculated using the Biot-Savart law.
Galvanometer01:24

Galvanometer

Common devices, including car instrument panels, battery chargers, and inexpensive electrical instruments, measure potential difference (voltage), current, or resistance using a d'Arsonval galvanometer. This electromechanical instrument is also known as a moving coil galvanometer.
The galvanometer consists of  two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform magnetic...
Magnetic Force On A Current-Carrying Conductor01:25

Magnetic Force On A Current-Carrying Conductor

Moving charges experience a force in a magnetic field. Since the magnetic fields produced by moving charges are proportional to the current, a conductor carrying a current creates a magnetic field around it.
Consider a compass placed near a current-carrying wire. The wire experiences a force that aligns the needle of the compass tangentially around the wire. Thus, the current-carrying wire produces concentric circular loops of magnetic field. The magnetic field generated by a wire can be...
Magnetic Field Due to Two Straight Wires01:18

Magnetic Field Due to Two Straight Wires

Consider two parallel straight wires carrying a current of 10 A and 20 A in the same direction and separated by a distance of 20 cm. Calculate the magnetic field at a point "P2", midway between the wires. Also, evaluate the magnetic field when the direction of the current is reversed in the second wire.

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Reply to Sanders et al.

American journal of physiology. Gastrointestinal and liver physiology·2026
Same author

Optical Mapping of Pacing-Elicited Slow Waves in the Swine Stomach: Role of Virtual Electrodes.

Neurogastroenterology and motility·2026
Same author

Effect of carbamazepine on the pharmacokinetics of vepdegestrant, a PROteolysis TArgeting Chimera estrogen receptor degrader, in healthy adults.

British journal of clinical pharmacology·2026
Same author

Finite-Time Admittance Control for Adaptive Compliance of a Soft Actuator of Robotic Gastric Simulator.

Soft robotics·2026
Same author

Wavelet-Based Denoising Optimization for Endoscopic Gastric Slow-Wave Recordings.

Healthcare technology letters·2026
Same author

Simultaneous high-resolution electrophysiology measurements and motion tracking of ex vivo rat uterine smooth muscle activity.

Reproduction (Cambridge, England)·2026
Same journal

Analysis of End-Tidal CO2 Variability During Plateau Waves Episodes: An Information Theoretic Approach<sup></sup>.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

AI and Tomosynthesis for Breast Cancer Molecular Subtyping: A step toward precision medicine<sup></sup>.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Towards Sustainable Protein Recovery from Biological Waste: Assessing Polyethersulfone-based Microfiltration.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Analysis of the cardiovascular response to standardized polymicrobial peritonitis experimental model.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Automated Wrist Ultrasound Image Bone Enhancement and Segmentation Using Deep Learning.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

A Deep Learning approach for Depressive Symptoms assessment in Parkinson's disease patients using facial videos.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
See all related articles

Related Experiment Video

Updated: Jun 18, 2026

Measuring the Influence of Magnetic Vestibular Stimulation on Nystagmus, Self-Motion Perception, and Cognitive Performance in a 7T MRT
08:57

Measuring the Influence of Magnetic Vestibular Stimulation on Nystagmus, Self-Motion Perception, and Cognitive Performance in a 7T MRT

Published on: March 3, 2023

Volume conductor effects on simulated magnetogastrograms.

Wenlian Qiao1, Rié Komuro, Andrew J Pullan

  • 1Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand. wqia007@aucklanduni.ac.nz

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
|December 8, 2009
PubMed
Summary
This summary is machine-generated.

Accurate modeling of magnetic fields from gastric electrical activity (GEA) requires an anatomically realistic torso model. Simplified models produce significantly different results, impacting GEA research.

More Related Videos

Cardiac Magnetic Resonance Imaging at 7 Tesla
09:14

Cardiac Magnetic Resonance Imaging at 7 Tesla

Published on: January 6, 2019

The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
13:56

The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism

Published on: November 19, 2014

Related Experiment Videos

Last Updated: Jun 18, 2026

Measuring the Influence of Magnetic Vestibular Stimulation on Nystagmus, Self-Motion Perception, and Cognitive Performance in a 7T MRT
08:57

Measuring the Influence of Magnetic Vestibular Stimulation on Nystagmus, Self-Motion Perception, and Cognitive Performance in a 7T MRT

Published on: March 3, 2023

Cardiac Magnetic Resonance Imaging at 7 Tesla
09:14

Cardiac Magnetic Resonance Imaging at 7 Tesla

Published on: January 6, 2019

The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
13:56

The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism

Published on: November 19, 2014

Area of Science:

  • Biophysics
  • Medical Imaging
  • Computational Electromagnetics

Background:

  • Gastric electrical activity (GEA) generates weak magnetic fields.
  • Accurate modeling of these fields is crucial for understanding gastrointestinal function and disease.
  • Previous studies have used simplified models for volume conduction, potentially limiting accuracy.

Purpose of the Study:

  • To simulate and compare magnetic fields generated by GEA using different volume conductor models.
  • To assess the necessity of anatomically realistic models for accurate GEA magnetic field calculations.

Main Methods:

  • Simulated GEA using a moving dipole source.
  • Employed simplified volume conductor models (free-space, spherical, half-space).
  • Utilized an anatomically realistic torso model for comparison.
  • Analyzed patterns and directions of the resultant magnetic fields.

Main Results:

  • Simplified models yielded magnetic field patterns and directions distinct from the realistic model.
  • Significant discrepancies were observed between simplified and anatomically realistic model outputs.
  • The choice of volume conductor model critically influences simulated GEA magnetic fields.

Conclusions:

  • Anatomically realistic torso models are essential for accurate simulation of magnetic fields from GEA.
  • Simplified models are insufficient for precise GEA magnetic field modeling.
  • This finding underscores the importance of realistic modeling in bioelectromagnetism research.