Related Experiment Video
Updated: Aug 10, 2026

Confirmation of Myocardial Ischemia and Reperfusion Injury in Mice Using Surface Pad Electrocardiography
Published on: November 24, 2016
Baroreflex sensitivity and electrophysiological correlates in patients after acute myocardial infarction
T G Farrell1, V Paul, T R Cripps
1Department of Cardiological Sciences, St. George's Hospital, London, UK.
Background:
Several studies have identified transient disturbances of autonomic function during the acute and recovery phases of myocardial infarction, and it has recently been suggested that survivors of acute myocardial infarction with depressed vagal tone may be at increased risk of sudden or arrhythmic death.
Methods And Results:
To investigate this hypothesis, parasympathetic function was assessed by arterial baroreflex sensitivity (BRS) testing (using the phenylephrine method) and by heart rate variability (HRV) analysis from 24-hour Holter recording in 68 patients at day 7-10 after infarction. The relation between autonomic tone and markers of arrhythmic propensity, including programmed ventricular stimulation (PVS) and late potentials in addition to other clinical variables, was examined. BRS for the whole group was 7.0 +/- 4.7 msec/mm Hg and was inversely correlated with age (r = 0.53, p less than 0.001) but not with left ventricular ejection fraction (r = 0.035, p = NS). In those patients in whom sustained monomorphic ventricular tachycardia (SMVT) was induced, BRS was significantly reduced (p = 0.001) as was HRV (p = 0.007) and left ventricular ejection fraction (p = 0.022). The strongest association between any variable (including HRV, BRS, late potentials, left ventricular ejection fraction, exercise testing, Q waves, and infarct site) and the induction of sustained monomorphic ventricular tachycardia was depressed BRS with a relative risk of 36.28 (95% confidence interval, 5-266).
Conclusions:
This study confirms that depressed BRS identifies a subgroup at high risk for arrhythmic events after myocardial infarction and that programmed ventricular stimulation may be safely limited to this group without any loss of predictive accuracy.
More Related Videos
09:56Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
08:33Bidirectional Electrical and Optoelectronic Interfaces in Healthy and Ischemic Ex Vivo Rat Hearts
Published on: July 18, 2025