Oxygen delivery to patients after cardiac surgery: a medical record audit
Glenn M Eastwood1, Bev O'Connell, Julie Considine
1Intensive Care Unit, Austin Hospital, Melbourne, VIC. glenn.eastwood@austin.org.au
Objective:
To describe how intensive care nurses manage the administration of supplemental oxygen to patients during the first 24 hours after cardiac surgery.
Methods:
A retrospective audit was conducted of the medical records of 245 adult patients who underwent cardiac surgery between 1 January 2005 and 31 May 2008 in an Australian metropolitan hospital. Physiological data (oxygen saturation measured by pulse oximetry and respiratory rate) and intensive care unit management data (oxygen delivery device, oxygen flow rate and duration of mechanical ventilation) were collected at hourly intervals over the first 24 hours of ICU care.
Results:
Of the 245 patients whose records were audited, 185 were male; mean age was 70 years (SD, 10), and mean APACHE II score was 17.5 (SD, 5.14). Almost half the patients (122, 49.8%) were extubated within 8 hours of ICU admission. The most common oxygen delivery device used immediately after extubation was the simple face mask (214 patients, 87%). Following extubation, patients received supplemental oxygen via, on average, two different delivery devices (range, 1-3), and had the delivery device changed an average of 1.38 times (range, 0-6) during the 24 hours studied. Twenty-two patients (9%) received non-invasive ventilation or high-flow oxygen therapy, and 16 (7%) experienced one or more episode of hypoxaemia during mechanical ventilation. A total of 148 patients (60%) experienced one or more episodes of low oxygenation or abnormal respiratory rate during the first 24 hours of ICU care despite receiving supplemental oxygen.
Conclusion:
These findings suggest that the ICU environment does not protect cardiac surgical patients from suboptimal oxygen delivery, and highlights the need for strategies to prompt the early initiation of interventions aimed at optimising blood oxygen levels in cardiac surgical patients in the ICU.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...