Noninvasive haemodynamic monitoring using finger arterial pressure waveforms
R M de Jong1, B E Westerhof, A A Voors
1Department of Cardiology, University Medical Centre Groningen/University of Groningen, the Netherlands. R.M.de.Jong@thorax.umcg.nl
Abstract:
Haemodynamic monitoring may potentially lead to improved quality of care in haemodynamic compromised patients. However, the usefulness of invasive techniques using the pulmonary artery catheter is questioned. Noninvasive techniques which provide data on haemodynamics might provide a good alternative. New techniques have been developed in recent years to monitor cardiac output and other parameters of cardiac performance continuously and noninvasively. Recently, a new technique has become available that assesses these haemodynamic data from finger arterial pressure waveforms obtained noninvasively. Although an invasively derived calibration is still needed to obtain absolute data on cardiac output, relative changes in cardiac output can be accurately monitored using this method. Currently, the device can be used in patients to continuously monitor haemodynamic data and guide therapy. Furthermore, it might have a role in clinical research to noninvasively assess cardiac output, as a surrogate endpoint, before and after interventions. Although this new method seems promising, the clinical value has to be proven.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement