Determination of fluoride using ion-selective electrodes in the presence of aluminum
Siqingaowa Borjigin1, Yuuta Ashimura, Toshiaki Yoshioka
1Graduate School of Environmental Studies, Tohoku University, 6-6-7 Aramaki Aza Aoba, Aoba, Sendai 980-8579, Japan.
Abstract:
We describe a method for determining fluoride with ion-selective electrodes (ISEs). Tartrate and Tris-based total ionic strength adjustment buffers (TISABs) were found to lower the interference from aluminum to a greater extent than conventional citrate-based TISABs. We adopted a solid TISAB addition method that is simple to perform, and can be carried out without lowering the level of fluoride. The apparent recovery of fluoride was 95% or higher, even at 500 mg L(-1) of Al3+ when a tartrate and Tris-based TISAB was used. Interferences from common ions were not observed at 100 mg L(-1) levels. We determined the fluoride content in solid silicate samples with ISEs without preliminary steam distillation after alkali fusion processing. Adding a solid TISAB mixture consisting of tartaric acid, sodium tartrate, and Tris, however, eliminated any interference from high levels of aluminum and sodium and potassium carbonates. The proposed analytical method was also applied to the determination of fluoride in geochemical reference samples.
More Related Videos
12:02Determination of Thermodynamic Properties of Alkaline Earth-liquid Metal Alloys Using the Electromotive Force Technique
Published on: November 3, 2017
05:50Facile Preparation of Ultrafine Aluminum Hydroxide Particles with or without Mesoporous MCM-41 in Ambient Environments
Published on: May 11, 2017
Related Concept Videos
EDTA: Indirect and Alkalimetric Titration
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Qualitative Analysis
For instance, group IV...
EDTA: Auxiliary Complexing Reagents