Effects of instrumental dead space reduction during weaning from synchronized ventilation in preterm infants
Objective:
A majority of the modalities of synchronized ventilation in preterm infants require the use of flow sensors that can increase dead space and may adversely affect ventilator weaning. The objective of this study was to assess the effects of flow sensor dead space during synchronized intermittent mandatory ventilation (SIMV) weaning in preterm infants.
Study Design:
Twelve preterm infants (gestational age 25+/-2 weeks, birth weight 705+/-158 g, age: 31+/-186 days, SIMV rate: 25+/-8 breaths min(-1), peak inspiratory pressure 18+/-2 cm H(2)O, positive end-expiratory pressure: 5+/-0.5 cm H(2)O, pressure support: 9+/-3 cm H(2)O, fraction of inspired oxygen: 34+/-6%) underwent two 2.5-h weaning periods during which SIMV rate was reduced twice by 5 breaths min(-1) at 30-min intervals as tolerated, with and without reduction of flow sensor dead space, in random sequence. A 30-min baseline was obtained before each weaning period. Dead space was reduced by flushing the flow sensor with a continuous gas leak flow in the endotracheal tube connector.
Result:
Transcutaneous CO(2) tension during SIMV weaning periods without and with reduced dead space did not differ from baseline, whereas total minute ventilation and tidal volume were lower during the SIMV weaning period with reduced dead space. Three infants did not tolerate SIMV weaning without while one infant did not tolerate weaning with reduced dead space.
Conclusion:
SIMV weaning elicited a compensatory rise in spontaneous ventilation. When flow sensor dead space was reduced during SIMV weaning, gas exchange was maintained with lower minute ventilation. Instrumental dead space imposes a ventilatory burden during SIMV weaning in small preterm infants.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Pulmonary Cycle: Exhalation