In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
Derivation and prospective testing of a two-step sevoflurane-O2-N2O low fresh gas flow sequence
T van Zundert1, A Brebels, J Hendrickx
1Department of Anaesthesiology, Intensive Care and Pain Therapy, University of Maastricht, Maastricht, The Netherlands.
Abstract:
Simple vaporiser setting (F(D)) and fresh gas flow (FGF) sequences make the practice of low-flow anaesthesia not only possible but also easy to achieve. We sought to derive a sevoflurane F(D) sequence that maintains the end-expired sevoflurane concentration (F(A)sevo) at 1.3% using the fewest possible number of F(D) adjustments with a previously described O2-N2O FGF sequence that allows early FGF reduction to 0.7 l min(-1). In 18 ASA physical status I to IH patients, F(D) was determined to maintain F(A)sevo at 1.3% with 2 l min(-1) O2 and 4 l min(-1) N2O FGF for three minutes, and with 0.3 and 0.4 l min(-1) thereafter. Using the same FGF sequence, the F(D) schedule that approached the 1.3% F(A)sevo pattern with the fewest possible adjustments was prospectively tested in another 18 patients. The following F(D) sequence approximated the F(D) course well: 2% from zero to three minutes, 2.6% from three to 15 minutes and 2.0% after 15 minutes. When prospectively tested, median (25th; 75th percentile) performance error was 0.8 (-2.9; 5.9)%, absolute performance error 6.7 (3.3; 10.6)%, divergence 18.2 (-5.6; 27.4)%.h(-1) and wobble 4.4 (1.7; 8.1) %. In one patient, FGF had to be temporarily increased for four minutes. One O2/N2O rotameter FGF setting change from 6 to 0.7 l min(-1) at three minutes and two sevoflurane F(D) changes at three and 15 minutes maintained predictable anaesthetic gas concentrations during the first 45 minutes in all but one patient in our study.
More Related Videos
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
03:02Application of Dixon's Up-and-Down Design to Estimate the Minimum Alveolar Concentration of Sevoflurane in Rats with Refined Movement Classification
Published on: July 25, 2025
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Inhalational Anesthetics: Overview
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Tracheostomy Suctioning II: Procedure