Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Variability of left ventricular electromechanical activation during right ventricular pacing: implications for the
Gianni Pastore1, Francesco Zanon, Franco Noventa
1Department of Cardiology, Rovigo General Hospital, Rovigo, Italy. gian.past@libero.it
Background:
The right ventricular septum (RVS) and Hisian area (HA) are considered more "physiological" pacing sites than right ventricular apex (RVA). Studies comparing RVS to RVA sites have produced controversial results. There are no data about variability of electromechanical activation obtained by an approach using fluoroscopy and electrophysiological markers. This study compared the variability of left ventricular (LV) electromechanical activation in patients undergoing short-term RVA and RVS with that measured during HA pacing based on fluoroscopy and electrophysiological markers.
Methods:
Tissue Doppler echocardiography was performed in 142 patients before and after RVA (54), RVS (44), and HA (44) pacing. Electromechanical activation was assessed by: (1) electromechanical latency (EML)-interval between QRS onset and mechanical activation of basal LV; (2) intra-LV dyssynchrony (intra-LV)-interval between earliest to the latest LV basal motion. The intra- and interpatients variability among pacing groups were assessed.
Results:
Pacing from RVA showed longer EML and higher degree of intra-LV than RVS and HA pacing. RVA and RVS showed a higher variability than HA pacing with regard to intrapatient changes of EML (RVA vs RVS, P = 0.4; RVS vs HA, P = 0.01, RVA vs HA, P = 0.0002) and intra-LV (RVA vs RVS, P = 0.2; RVS vs HA, P = 0.04; RVA vs HA, P = 0.005). Similar results were found in interpatients variability from paced-values.
Conclusions:
RVA and RVS pacing produce a variable effect on LV electromechanical activation that is significantly more pronounced than HA pacing. A pacing site such as HA selected by fluoroscopic and electrophysiological markers maintains baseline and homogeneous LV activation pattern.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...