The relationship between fetal biophysical assessment, umbilical artery velocimetry, and fetal acidosis
A M Vintzileos1, W A Campbell, J F Rodis
1Department of Obstetrics and Gynecology, University of Connecticut Health Center, Farmington.
In a prospective study of 62 patients undergoing cesarean delivery before the onset of labor, fetal biophysical assessment and umbilical artery systolic-diastolic ratios (S/Ds) were performed within 3 hours of delivery. There was a significant relationship between the fetal biophysical profile score and cord arterial as well as cord venous pH. However, there was no identifiable relationship between S/D and cord arterial or venous pH. The efficacies of the biophysical components alone (nonstress test [NST] and fetal biophysical profile) and in combination with S/D to predict fetal acidosis were determined. The NST had the best sensitivity (100%) and negative predictive value (100%). The fetal biophysical profile had the best specificity (91%), positive predictive value (62%), and overall efficiency (90%). The S/D had the lowest sensitivity (66%), specificity (42%), positive predictive value (16%), negative predictive value (88%), and overall efficiency (45%). The addition of S/D to the NST or fetal biophysical profile did not improve diagnostic accuracy. These data suggest that the NST should be used as a primary test for the antepartum detection of fetal acidosis, whereas the fetal biophysical profile is a reasonable adjunct test. The umbilical artery S/D, as determined by continuous-wave Doppler velocimetry, has no value as a primary method or an adjunct in the antepartum detection of fetal acidosis.
In a prospective study of 62 patients undergoing cesarean delivery before the onset of labor, fetal biophysical assessment and umbilical artery systolic-diastolic ratios (S/Ds) were performed within 3 hours of delivery. There was a significant relationship between the fetal biophysical profile score and cord arterial as well as cord venous pH. However, there was no identifiable relationship between S/D and cord arterial or venous pH. The efficacies of the biophysical components alone (nonstress test [NST] and fetal biophysical profile) and in combination with S/D to predict fetal acidosis were determined. The NST had the best sensitivity (100%) and negative predictive value (100%). The fetal biophysical profile had the best specificity (91%), positive predictive value (62%), and overall efficiency (90%). The S/D had the lowest sensitivity (66%), specificity (42%), positive predictive value (16%), negative predictive value (88%), and overall efficiency (45%). The addition of S/D to the NST or fetal biophysical profile did not improve diagnostic accuracy. These data suggest that the NST should be used as a primary test for the antepartum detection of fetal acidosis, whereas the fetal biophysical profile is a reasonable adjunct test. The umbilical artery S/D, as determined by continuous-wave Doppler velocimetry, has no value as a primary method or an adjunct in the antepartum detection of fetal acidosis.
Related Concept Videos
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...