Related Experiment Videos

Stability of miconazole in peritoneal dialysis fluid

S E Holmes1, S Aldous

  • 1School of Pharmacy, University of Tasmania, Australia.

American Journal of Hospital Pharmacy
|February 1, 1991
PubMed

Insights

Miconazole stability is compromised in polyvinyl chloride (PVC) bags when mixed with peritoneal dialysis (PD) fluid, leading to rapid drug loss. Glass ampuls offer superior stability for miconazole PD admixtures.

Area of Science:

  • Pharmaceutical Science
  • Clinical Pharmacy

Background:

  • Miconazole is an antifungal agent.
  • Peritoneal dialysis (PD) is a treatment for kidney failure.
  • The stability of drug admixtures in PD fluid is crucial for patient safety.

Purpose of the Study:

  • To assess the stability of miconazole when mixed with PD fluid.
  • To compare the stability of miconazole in polyvinyl chloride (PVC) bags versus glass ampuls.

Main Methods:

  • Miconazole was mixed with PD fluid to a concentration of 20 mg/mL.
  • Admixtures were stored in PVC bags and glass ampuls at 20°C.
  • High-performance liquid chromatography (HPLC) was used to assay miconazole concentrations over nine days.

Main Results:

  • Miconazole loss exceeded 10% within four hours in PVC bags.
  • Over 90% of miconazole remained stable in glass ampuls for at least three days.
  • Methanolic extraction recovered approximately 28% of the lost miconazole from PVC bags, indicating container interaction.

Conclusions:

  • Miconazole is unstable in PD fluid when stored in PVC bags due to interaction with the plastic.
  • Glass ampuls provide a more stable storage option for miconazole PD admixtures.
  • Miconazole PD admixtures should be prepared immediately prior to administration when using PVC bags.