A detection method for streak artifacts and radiological noise in a non-uniform region in a CT image
Kuniharu Imai1, Mitsuru Ikeda, Yukihiro Enchi
1Department of Radiological Technology, Nagoya University School of Health Sciences, 1-20 Daikominami 1-chome, Higashi-ku, Nagoya, 461-8673, Japan.
Abstract:
By using the CT images obtained by subtracting two CT images acquired under the same conditions and slice locations, we have devised a method for detecting streak artifacts in non-uniform regions and only radiological noise components in CT images. A chest phantom was scanned using 16- and 64-multidetector row helical CT scanners with various mAs values at 120kVp. The upper lung slice image was employed as a target image for evaluating the streak artifacts and radiological noise. One hundred parallel line segments with a length of 80 pixels were placed on the subtracted CT image, and the largest CT value in each CT value profile was employed as a feature variable of the streak artifacts; these feature variables were analyzed with the extreme value theory (Gumbel distribution). To detect only the radiological noise, all CT values contained in the 100 line profile were plotted on normal probability paper and the standard deviation was estimated from the inclination of its fitted line for the CT value plots. The two detection methods devised in this study were able to evaluate the streak artifacts and radiological noise in the CT images with high accuracy.
More Related Videos
07:013D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
Published on: October 24, 2019
09:55Troubleshooting and Quality Assurance in Hyperpolarized Xenon Magnetic Resonance Imaging: Tools for High-Quality Image Acquisition
Published on: January 5, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Magnetic Resonance Imaging