Related Experiment Video
Updated: Jun 17, 2026

Effects of Surgical Masks on Cardiopulmonary Function in Healthy Subjects
Published on: February 12, 2021
Comparison of gas exchange data using the Aquatrainer system and the facemask with Cosmed K4b2 during exercise in
Mathieu Gayda1, Laurent Bosquet, Martin Juneau
1Montreal Heart Institute Cardiovascular and Prevention Center (Centre EPIC), Université de Montréal, 5055 St-Zotique Street East, Montreal, QC H1T 1N6, Canada. mathieu.gayda@icm-mhi.org
Abstract:
The aim of this study was to determine the level of agreement between the new Aquatrainer system and the facemask in the assessment of submaximal and maximal cardiopulmonary responses during exercise performed on ergocycle. Twenty-six physically active healthy subjects (mean age: 41 +/- 14 years) performed a submaximal constant work test followed by maximal incremental exercise test on ergocycle, one with cardiopulmonary responses measured using the Cosmed K4b2 facemask, the other using the Cosmed K4b2 Aquatrainer. Using the Aquatrainer, the gas exchange variables at 100 W were significantly lower for VO(2) (1,483 +/- 203 vs. 1,876 +/- 204 ml min(-1), P < 0.0001), VCO(2) (1,442 +/- 263 vs. 1,749 +/- 231 ml min(-1), P < 0.0001), VE (38 +/- 5 vs. 44 +/- 6 l min(-1), P < 0.0001), and VT (1.92 +/- 0.47 vs. 2.18 +/- 0.41 l, P < 0.0001) relative to facemask. The bias +/-95% limits of agreement (LOA) for VO(2) was 393 +/- 507 ml min(-1) for the submaximal constant work test at 100 W and 495 +/- 727 ml min(-1) for VO(2max). At maximal intensity, cardiopulmonary responses measured with the Aquatrainer system were significantly lower for: VO(2) (2,799 +/- 751 vs. 3,294 +/- 821 ml min(-1), P < 0.0001), VCO(2) (3,426 +/- 836 vs. 3,641 +/- 946 ml min(-1), P = 0.012), VE (98 +/- 21 vs. 108 +/- 26 l min(-1), P = 0.0009) relative to facemask. A non-constant measurement error [interaction effect: (facemask or aquatrainer) x power] was noted from 60 to 270 W for VO(2) (ml min(-1)), VCO(2) (ml min(-1)), ventilation (l min(-1)) (P < 0.0001) and VT (l, P = 0.0001). Additional studies are required to detect the main sources of error that could be physical and/or physiological in nature. Due to the significant measurement error, the new Aquatrainer system should be used with extreme caution in filed testing conditions of swimmers.
More Related Videos
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
08:44Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
Published on: February 2, 2024
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Respiratory Volumes and Capacities
Respiration and Gaseous Exchange
Respiration involves the exchange of gases, especially oxygen (O2) and carbon dioxide (CO2), between the alveoli and body cells, a process facilitated by blood circulation. As a result, the cardiovascular system, which involves the...