Related Experiment Video
Updated: Jun 17, 2026

The Role of Indocyanine Green Fluorescence in Complex Laparoscopic Cholecystectomy Navigation
Published on: January 31, 2025
Sincalide-stimulated cholescintigraphy: a multicenter investigation to determine optimal infusion methodology and
Harvey A Ziessman1, Mark Tulchinsky, William C Lavely
1Johns Hopkins University, Division of Nuclear Medicine, Russell H. Morgan Department of Radiology and Radiologic Science, Baltimore, Maryland, USA. hziessm1@jhmi.edu
Unlabelled:
Sincalide-stimulated cholescintigraphy is performed to quantify gallbladder contraction and emptying. However, different infusion methods are used for this study. Our purpose was to determine the infusion method with the least variability (smallest coefficient of variation [CV]) for calculation of the gallbladder ejection fraction (GBEF) in healthy subjects and to establish normal values.
Methods:
Sixty healthy volunteers at 4 medical centers were injected intravenously with (99m)Tc-mebrofenin. After gallbladder visualization had been confirmed at 60 min, 0.02 microg of sincalide per kilogram was administered using 3 different infusion durations, 15, 30, and 60 min, each performed on separate days. The CV, mean, SD, first to 99th percentile, and fifth to 95th percentile were calculated. GBEF normal values were determined for the different infusion durations.
Results:
The CV was smallest for the 60-min infusion at 60 min (19%; 95% confidence interval [CI], 16%-23%), compared with the 30-min infusion at 30 min (35%; 95% CI, 29.2%-42.1%) and the 15-min infusion at 15 min (52%; 95% CI, 44%-63%). These were all significantly different (P < 0.0007). For the 60-min infusion at 60 min, the lower limit of normal for the GBEF was 38% defined at the 1% CI.
Conclusion:
The GBEF at 60 min has the lowest CV in healthy subjects, compared with shorter infusions of 15 or 30 min. This multicenter trial establishes a GBEF lower limit of normal of 38% (first percentile) for a 60-min infusion of 0.02 microg of sincalide per kilogram, quantified at 60 min. Using this infusion method minimizes the variability in measured GBEFs. This sincalide infusion method should become the standard for routine clinical use.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...