Abstract:
In this study, a simple mathematical-statistical based metric called Multiple Higher Order Moments (MHOM) is introduced enabling the electrocardiogram (ECG) detection-delineation algorithm to yield acceptable results in the cases of ambulatory holter ECG including strong noise, motion artifacts, and severe arrhythmia(s). In the MHOM measure, important geometric characteristics such as maximum value to minimum value ratio, area, extent of smoothness or being impulsive and distribution skewness degree (asymmetry), occult. In the proposed method, first three leads of high resolution 24-h holter data are extracted and preprocessed using Discrete Wavelet Transform (DWT). Next, a sample to sample sliding window is applied to preprocessed sequence and in each slid, mean value, variance, skewness, and kurtosis of the excerpted segment are superimposed called MHOM. The MHOM metric is then used as decision statistic to detect and delineate ECG events. To show advantages of the presented method, it is applied to MIT-BIH Arrhythmia Database, QT Database, and T-Wave Alternans Database and as a result, the average values of sensitivity and positive predictivity Se = 99.95% and P+ = 99.94% are obtained for the detection of QRS complexes, with the average maximum delineation error of 6.1, 4.1, and 6.5 ms for P-wave, QRS complex, and T-wave, respectively showing marginal improvement of detection-delineation performance. In the next step, the proposed method is applied to DAY hospital high resolution holter data (more than 1,500,000 beats including Bundle Branch Blocks--BBB, Premature Ventricular Complex--PVC, and Premature Atrial Complex-PAC) and average values of Se = 99.97% and P+ = 99.95% are obtained for QRS detection. In summary, marginal performance improvement of ECG events detection-delineation process, reliable robustness against strong noise, artifacts, and probable severe arrhythmia(s) of high resolution holter data can be mentioned as important merits and capabilities of the proposed algorithm.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Holter Monitor: 24-Hour Monitoring