Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

IR Spectrometers01:25

IR Spectrometers

There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
IR Spectroscopy: Molecular Vibration Overview01:24

IR Spectroscopy: Molecular Vibration Overview

When Infrared (IR) radiation passes through a covalently bonded molecule, the bonds transition from lower to higher vibrational levels. The fundamental vibrational motions that result in infrared absorption can be classified as stretching or bending vibrations.
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

All-reflection Michelson interferometer: analysis and test for far ir Fourier spectroscopy.

Applied optics·2010
Same author

Cryogenic infrared grating spectrometer.

Applied optics·2010
Same author

High contrast in a polyetalon fabry-perot spectrometer.

Applied optics·2010
Same author

Effects of oxcarbazepine on cognitive function in children and adolescents with partial seizures.

Neurology·2006

Related Experiment Video

Updated: Jun 16, 2026

Fabrication of a Low-Cost, Fiber-Coupled, and Air-Spaced Fabry-Pérot Etalon
07:22

Fabrication of a Low-Cost, Fiber-Coupled, and Air-Spaced Fabry-Pérot Etalon

Published on: February 3, 2023

A twelve-channel multiple-interferometer fabry-perot spectrometer.

M Daehler

    Applied Optics
    |January 23, 2010
    PubMed
    Summary

    A novel spectrometer using multiple Fabry-Perot interferometers achieves high spectral resolution for plasma diagnostics. This system effectively analyzes scattered, Doppler-broadened laser light from theta-pinch plasma experiments.

    Area of Science:

    • Plasma Physics
    • Spectroscopy
    • Optical Instrumentation

    Background:

    • Plasma diagnostics require high spectral resolution and temporal accuracy.
    • Existing spectroscopic methods may not meet the demands of complex plasma experiments.

    Purpose of the Study:

    • To develop and present a specialized spectrometer tailored for challenging plasma diagnostic experiments.
    • To achieve high spectral resolution and contrast for analyzing plasma light emissions.

    Main Methods:

    • Construction of a specialized spectrometer featuring two or three series-arranged Fabry-Perot interferometers.
    • Utilizing an annular mirror image dissector for twelve-channel output.
    • Employing gas pressure changes within interferometer chambers to shift the spectral region.

    More Related Videos

    A Multimodal Wide-Field Fourier-Transform Raman Microscope
    06:48

    A Multimodal Wide-Field Fourier-Transform Raman Microscope

    Published on: December 30, 2025

    High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
    13:31

    High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis

    Published on: December 22, 2015

    Related Experiment Videos

    Last Updated: Jun 16, 2026

    Fabrication of a Low-Cost, Fiber-Coupled, and Air-Spaced Fabry-Pérot Etalon
    07:22

    Fabrication of a Low-Cost, Fiber-Coupled, and Air-Spaced Fabry-Pérot Etalon

    Published on: February 3, 2023

    A Multimodal Wide-Field Fourier-Transform Raman Microscope
    06:48

    A Multimodal Wide-Field Fourier-Transform Raman Microscope

    Published on: December 30, 2025

    High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
    13:31

    High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis

    Published on: December 22, 2015

    Main Results:

    • Demonstration of the spectrometer's capability to provide high spectral resolution and contrast.
    • Presentation of passband profiles measured using two interferometers.
    • Sample data illustrating the analysis of ruby laser light scattered and Doppler-broadened by theta-pinch plasma.

    Conclusions:

    • The developed specialized spectrometer meets the stringent requirements for difficult plasma diagnostic experiments.
    • The instrument is capable of accurately measuring the spectral characteristics of plasma-influenced light.