Related Experiment Video
Updated: Jun 26, 2026

Local Field Fluorescence Microscopy: Imaging Cellular Signals in Intact Hearts
Published on: March 8, 2017
Alternans of epicardial repolarization as a localized phenomenon in man
1Department of Physiology, University College & Middlesex School of Medicine, London, U.K.
Abstract:
Electrophysiological alternans (beat-to-beat alternation of the configuration of the action potential and/or electrocardiogram) may be important in the causation of ventricular arrhythmias. We recorded monophasic action potentials from the left ventricular epicardium in patients undergoing routine cardiac surgery. We set out to determine: (a) whether a small increase in atrial pacing rate could elicit electrophysiological alternans; (b) whether different phases of the operation influence the incidence and; (c) whether electrical alternans was a localized phenomenon. Thirty-six patients were studied, and alternans of action potential duration was observed in 14 (39%). The difference between alternate long and short action potential durations ranged from 4 to 112 ms. The mean differences during each stage of the protocol were: pacing before bypass 33.3 +/- 22.7 ms (three of 17 patients); pacing after bypass 46.7 +/- 37.8 ms (nine of 36 patients); pacing during transient graft occlusion 28.0 +/- 23.1 ms (five of 17 patients); pacing following release of the grafts 29.6 +/- 30.0 ms (five of 17 patients). None of the patients showed any evidence of alternans in the electrocardiogram or mechanical alternans in radial artery pressure. In seven of the 14 patients showing alternans, recordings were made in closely adjacent (approximately 1 cm) areas showing that alternans could be a localized phenomenon. The findings indicate that electrical alternans was a frequent occurrence in this study (39% of patients) and may be a localized phenomenon.
More Related Videos
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials

