Background:
Three-dimensional imaging of the cornea under physiological conditions is best performed with intrinsic contrast mechanisms for the visualisation of cells and extracellular matrix. However, the unique transparency of the cornea goes along with a lack of contrast for the extracellular matrix (ECM) in reflective mode microscopy and optical coherence tomography.
Methods:
Femtosecond laser-based non-linear microscopy provides novel contrast mechanisms for the visualisation of ECM. The confinement of the non-linear contrast to the focus volume provides an intrinsic sectioning property for 3D imaging. Further advantages of the infrared light are lower phototoxicity and higher penetration depth into the tissue. For the visualisation of the cornea and its layered substructures two non-linear contrast mechanisms are of main interest: Two-photon excited autofluorescence of NAD(P)H in the cytoplasma and second harmonic generation (SHG) in the collagen-I fibres of the stroma. Ex-vivo corneas of the rabbit were imaged to demonstrate the abilities of non-linear microscopy.
Results:
Using the autofluorescence of NAD(P)H the corneal epithelium with squamous cells, wing cells and basal cells is visualised in three dimensions without additional exogenoeus staining. Stromal keratocytes are also imaged using the NAD(P)H autofluoresecence. The layered structure of lamella in the stroma is visible after virtual resclicing of the 3D volume data. The en-face SHG images detected through the transparent cornea in forward direction show areas of parallel streaks, which increase in size and periodically alter in orientation (90 degrees , 45 degrees) with increasing depth from anterior to posterior. These streaks are not visible in the backward SHG signal. First results on rabbit corneas, which were cross-linked with Rivoflavin and UV application showed a signature of treatment five weeks post treatment. There were zones in the stroma totally lacking NAD(P)H autofluorescence and the abundance of keratocytes was less homogeneous than in control corneas.
Conclusion:
These results and current reports on applications in the literature show that femtosecond laser-based non-linear microscopy is an emerging imaging modality which provides dye-free imaging of the corneal ECM and therefore complements scattering imaging modalities such as optical coherence tomography and confocal laser scanning microscopy in the reflective mode.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Confocal Fluorescence Microscopy
Total Internal Reflection Fluorescence Microscopy
Super-resolution Fluorescence Microscopy
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...