Thrombocytopenia associated with use of a biocompatible hemodialysis membrane: a case report
1Renal Division, James J. Peters Veterans Affairs Medical Center, Bronx, NY 10468, USA. james.post@va.gov
Biocompatibility of a dialyzer membrane has been defined largely by the degree to which it activates complement. Modifications of the cellulose membrane and the development of synthetic membranes have minimized the activation of complement and its associated complications. However, less is known about the blood-dialyzer membrane interactions that may occur in membranes made of the same synthetic polymer. A patient is described who developed dialysis-associated thrombocytopenia using a Fresenius Medical Care Optiflux polysulfone membrane (F-160) that significantly improved when switched to the polysulfone Asahi REXEED 25S membrane (AR-25S). A comparison of postdialysis d-dimer level suggests that the F-160 membrane activated the coagulation pathway to a greater extent than the AR-25S. Subtle differences between the internal surfaces of the membranes that are manufacturer specific may be responsible for exposing this patient's unique predisposition to thrombosis and thrombocytopenia. Despite the advances in membrane biocompatibility, differences may exist among membranes made of the same synthetic polymer.
Biocompatibility of a dialyzer membrane has been defined largely by the degree to which it activates complement. Modifications of the cellulose membrane and the development of synthetic membranes have minimized the activation of complement and its associated complications. However, less is known about the blood-dialyzer membrane interactions that may occur in membranes made of the same synthetic polymer. A patient is described who developed dialysis-associated thrombocytopenia using a Fresenius Medical Care Optiflux polysulfone membrane (F-160) that significantly improved when switched to the polysulfone Asahi REXEED 25S membrane (AR-25S). A comparison of postdialysis d-dimer level suggests that the F-160 membrane activated the coagulation pathway to a greater extent than the AR-25S. Subtle differences between the internal surfaces of the membranes that are manufacturer specific may be responsible for exposing this patient's unique predisposition to thrombosis and thrombocytopenia. Despite the advances in membrane biocompatibility, differences may exist among membranes made of the same synthetic polymer.
Related Concept Videos
Hemodialysis II: Procedure and Complications
Hemodialysis I: Introduction
Hemodialysis III: Nursing Management
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...