Load sharing properties of cervical pedicle screw-rod constructs versus lateral mass screw-rod constructs
Bradley J Dunlap1, Eldin E Karaikovic, Hyung-Soon Park
1Department of Orthopaedic Surgery, NorthShore University Healthcare System, 1000 Central Street, Suite 880, Evanston, IL 60201, USA. brdunlap@gmail.com
Abstract:
Lateral mass screws have a history of successful clinical use, but cannot always be used in the subaxial cervical spine. Despite safety concerns, cervical pedicle screws have been proposed as an alternative. Pedicle screws have been shown to be biomechanically stronger than lateral mass screws. No study, however, has investigated the load sharing properties comparing constructs using these screws. To investigate this, 12 fresh-frozen single cervical spine motion segments (C4-5 and C6-7) from six cadavers were isolated. They were randomized to receive either lateral mass or pedicle screw-rod constructs. After preloading, the segments were cyclically loaded with a uniplanar axial load from 0 to 90 N both with and without the construct in place. Pressure data at the disc space were continuously collected using a dynamic pressure sensor. The reduction in disc space pressure between the two constructs was calculated to see if pedicle screw and lateral mass screw-rod constructs differed in their load sharing properties. In both the pedicle screw and lateral mass screw-rod constructs, there was a significant reduction in the disc space pressures from the no-construct to construct conditions. The percentage decrease for the pedicle screw constructs was significantly greater than the percentage decrease for the lateral mass screw constructs for average pressure (p < or = 0.002), peak pressure (p < or = 0.03) and force (p < or = 0.04). We conclude that cervical pedicle screw-rod constructs demonstrated a greater reduction in axial load transfer through the intervertebral disc than lateral mass screw-rod constructs. Though there are dangers associated with the insertion of cervical pedicle screws, their use might be advantageous in some clinical conditions when increased load sharing is necessary.
Related Concept Videos
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Construction of Root Locus
For positive gain values, the root locus exists on the real axis to the left of an odd number of finite open-loop poles or zeros. The root locus starts at the open-loop poles and traces the paths of the closed-loop poles as the gain...
Construction of Frequency Distribution
First, make a table with two columns—one with the title of the data that needs to be organized, and the other column for frequency. [Draw a third column for tally marks if needed]. Then, take a look at the items given in the data set and decide if an ungrouped frequency distribution table or a grouped frequency distribution table would be more suitable. If there are large sets of different values, then it is...
Bode Plots Construction