Integrated real-time monitoring system to investigate the hypoxia in a shallow wind-driven bay
Mohammad Shahidul Islam1, James S Bonner, Cheryl Page
1Science and Technology, Beacon Institute for Rivers and Estuaries, Beacon, NY, 12508, USA. sislam@bire.org
Abstract:
Corpus Christi Bay (Texas, USA) is a shallow wind-driven bay which experiences hypoxia (dissolved oxygen < 2 mg/L) during the summer. Since this bay is a very dynamic system, the processes that control the hypoxia can last on the order of hours to days. Monitoring systems installed on a single type of platform cannot fully capture these processes at the spatial and temporal scales of interest. Therefore, we have integrated monitoring systems installed on three different platform types: (1) fixed robotic, (2) mobile, and (3) remote. On the fixed robotic platform, an automated profiler system vertically moves a suite of water quality measuring sensors within the water column for continuous measurements. An integrated data acquisition, communication and control system has been configured on our mobile platform (research vessel) for synchronized measurements of hydrodynamic and water quality parameters at greater spatial resolution. In addition, a high-frequency radar system has been installed on remote platforms to generate surface current maps for the bay. With our integrated system, we were able to capture evidence of a hypoxic event in summer 2007; moreover, we detected low dissolved oxygen conditions in a part of the bay with no previously reported history of hypoxia.
More Related Videos
11:49Quantitative and Temporal Control of Oxygen Microenvironment at the Single Islet Level
Published on: November 17, 2013
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...