Related Experiment Video
Updated: Jun 16, 2026

Watershed Planning within a Quantitative Scenario Analysis Framework
Published on: July 24, 2016
Stream temperature response to three riparian vegetation scenarios by use of a distributed temperature validated
T R Roth1, M C Westhoff, H Huwald
1Department of Water Resource Engineering Oregon State University, 116 Gilmore Hall, Corvallis, Oregon 97331, USA. rothtra@engr.orst.edu
Abstract:
Elevated in-stream temperature has led to a surge in the occurrence of parasitic intrusion proliferative kidney disease and has resulted in fish kills throughout Switzerland's waterways. Data from distributed temperature sensing (DTS) in-stream measurements for three cloud-free days in August 2007 over a 1260 m stretch of the Boiron de Merges River in southwest Switzerland were used to calibrate and validate a physically based one-dimensional stream temperature model. Stream temperature response to three distinct riparian conditions were then modeled: open, in-stream reeds, and forest cover. Simulation predicted a mean peak stream temperature increase of 0.7 °C if current vegetation was removed, an increase of 0.1 °C if dense reeds covered the entire stream reach, and a decrease of 1.2 °C if a mature riparian forest covered the entire reach. Understanding that full vegetation canopy cover is the optimal riparian management option for limiting stream temperature, in-stream reeds, which require no riparian set-aside and grow very quickly, appear to provide substantial thermal control, potentially useful for land-use management.
More Related Videos
12:26Integrating Remote Sensing with Species Distribution Models; Mapping Tamarisk Invasions Using the Software for Assisted Habitat Modeling (SAHM)
Published on: October 11, 2016
08:49Manufacturing Simple and Inexpensive Soil Surface Temperature and Gravimetric Water Content Sensors
Published on: December 21, 2019
Related Concept Videos
Derivatives: Problem Solving
Responses to Heat and Cold Stress
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Responses to Drought and Flooding
Typical Model Studies
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...