Diagnosis of Budd-Chiari syndrome by pulsed Doppler ultrasound
L Bolondi1, S Gaiani, S Li Bassi
1I Clinica Medica, Universitá di Bologna, Italy.
Computed tomography and real-time ultrasonography may not be conclusive for the diagnosis of the Budd-Chiari syndrome; in many cases more information may be needed, especially on vascular alterations. Doppler ultrasonography provides qualitative data on flow direction and pattern, thereby contributing significantly to diagnosis. Eight cases in which hepatic vein patency was unclear and presence of intrahepatic vessels resembling hepatic veins raised problems of interpretation in real-time ultrasonography are described. In some cases, patency or occlusion of the upper portion of the inferior vena cava were difficult to identify with real-time ultrasonography. Doppler ultrasonographic investigation showed flow in the hepatic veins to be completely absent in two cases and reversed in another two. In the remaining four cases, a flat waveform was evident. Flow in the inferior vena cava was reversed in four cases and showed a flat waveform in three other cases. Portal vein thrombosis was detected in only one case, whereas the remaining seven patients showed slow hepatopetal flow. These findings demonstrate that absent or reversed flow in the hepatic veins and/or flat flow in the hepatic veins associated with reversed flow in the inferior vena cava may be considered diagnostic for the Budd-Chiari syndrome. For this series the sensitivity of Doppler ultrasonography was 87.5%.
Computed tomography and real-time ultrasonography may not be conclusive for the diagnosis of the Budd-Chiari syndrome; in many cases more information may be needed, especially on vascular alterations. Doppler ultrasonography provides qualitative data on flow direction and pattern, thereby contributing significantly to diagnosis. Eight cases in which hepatic vein patency was unclear and presence of intrahepatic vessels resembling hepatic veins raised problems of interpretation in real-time ultrasonography are described. In some cases, patency or occlusion of the upper portion of the inferior vena cava were difficult to identify with real-time ultrasonography. Doppler ultrasonographic investigation showed flow in the hepatic veins to be completely absent in two cases and reversed in another two. In the remaining four cases, a flat waveform was evident. Flow in the inferior vena cava was reversed in four cases and showed a flat waveform in three other cases. Portal vein thrombosis was detected in only one case, whereas the remaining seven patients showed slow hepatopetal flow. These findings demonstrate that absent or reversed flow in the hepatic veins and/or flat flow in the hepatic veins associated with reversed flow in the inferior vena cava may be considered diagnostic for the Budd-Chiari syndrome. For this series the sensitivity of Doppler ultrasonography was 87.5%.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Mitral Stenosis II: Clinical features and Diagnostic Tests
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Aneurysm II: Clinical Manifestations and Diagnostic Studies