Related Experiment Video
Updated: Jun 16, 2026

Oral Biofilm Formation on Different Materials for Dental Implants
Published on: June 24, 2018
[Clinical evaluation of denture made of pure titanium]
Xu Yang1, Jian-guo Tan, De-li Li
1Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing 100081, China.
Objective:
To evaluate the clinical effect of pure titanium used for complete denture and removable partial denture.
Methods:
Sixty edentulous patients were selected. Thirty patients in the test group for pure titanium denture and the other 30 in control for Co-Cr Alloy denture.
Results:
No significant differences in clinical effect between dental casting pure titanium and casting Co-Cr alloy used for complete denture or removable partial denture.
Conclusion:
Due to the properties and biocompatibility, pure titanium can be used for denture base and frameworks of removable partial denture.