A new evaluation tool for monitoring devices and its application to evaluate the implantable Doppler probe
Niklas Iblher1, Steffen U Eisenhardt, Vincenzo Penna
1Department of Plastic and Hand Surgery, University of Freiburg Medical Center, Freiburg, Germany. niklas.iblher@uniklinik-freiburg.de
Abstract:
Evaluation parameters for free flap monitoring devices are used inconsistently, leading to considerable confusion about the quality and applicability of these devices. A comparison of different systems and different clinical series is almost impossible. The ultimate questions that need to be answered are those regarding the efficiency and the effectiveness of the system. A new tool consisting of two simple parameters that sufficiently and comparably describe the quality of monitoring devices is developed. The flap failure reduction rate describes the percentage of saved flaps (effectiveness). The revision success rate describes the efficiency. Literature reevaluation shows inconsistent results, although all authors describe a positive experience. This shows the limited value of the classical parameters. Larger studies have flap failure reduction rates of 5 to 12% (5 to 12% of monitored flaps are saved). Revision success rates of 75 to 90% prove that the system is efficient enough in daily use. Reevaluation of the smaller reported series result in lower parameters, which shows that there is a significant learning curve for this device. The new parameters alleviate the confusion surrounding evaluation of monitoring systems by giving specific information about effectiveness and efficiency. The benefits of the implanted Doppler probe can now be clearly described. However, in several studies the benefit of the system is overrated.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...