Abstract:
A boron-doped diamond (BDD) electrode was used for the electroanalytical determination of estriol hormone in a pharmaceutical product and a urine sample taken during pregnancy by square-wave voltammetry. The optimized experimental conditions were: (1) a supporting electrolyte solution of NaOH at a pH of 12.0, and (2) a frequency of 20 Hz, a pulse height of 30 mV and a scan increment of 2 mV (for the square-wave parameters). The analytical curve was linear in the concentration range of 2.0 x 10(-7) to 2.0 x 10(-5) mol L(-1) (r=0.9994), with a detection limit of 1.7 x 10(-7) mol L(-1) and quantification limit of 8.5 x 10(-7) mol L(-1). Recoveries of estriol were in the range of 98.6-101.0%, for the pharmaceutical sample, and 100.2-103.4% for the urine sample, indicating no significant matrix interference effects on the analytical results. The accuracy of the electroanalytical methodology proposed was compared to that of the radioimmunoassay method. The values for the relative error between the proposed and standard methods were -7.29% for the determination of estriol in the commercial product and -4.98% in a urine sample taken during pregnancy. The results obtained suggest a reliable and interesting alternative method for electroanalytical determination of estriol in pharmaceutical products and urine samples taken during pregnancy using a boron-doped diamond electrode.
More Related Videos
09:00Electrochemical Detection of Deuterium Kinetic Isotope Effect on Extracellular Electron Transport in Shewanella oneidensis MR-1
Published on: April 16, 2018
10:48Electrochemical Preparation of Poly(3,4-Ethylenedioxythiophene) Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Related Concept Videos
Electrodeposition
Electrodeposition can...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...
Electrogravimetric Analysis: Overview
To test the completeness of the...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...