Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Two-Step Ensemble Convolutional Neural Networks for Colonoscopic Biopsy Classification Resembling Pathologists' Process.

Journal of Korean medical science·2026
Same author

Post-pandemic structural shifts in perinatal characteristics and outcomes.

Journal of perinatal medicine·2026
Same author

Closing the Gap in Pre-Exposure Prophylaxis Access for Sexual and Gender Minorities in South Korea: Implications for HIV Prevention Policy.

AIDS patient care and STDs·2026
Same author

Age-Related Differences in Chronic Rhinosinusitis: Inflammatory Profiles and Surgical Outcomes in Geriatric and Non-Geriatric Patients.

Clinical and experimental otorhinolaryngology·2026
Same author

A-stream glaucoma shunt versus trabeculectomy: 1-year results on efficacy and safety.

Scientific reports·2026
Same author

Unanchored by two hits: IFNγ and mechanical stress synergize to undermine melanocyte adhesion and promote vitiligo.

The British journal of dermatology·2026

Related Experiment Video

Updated: Dec 22, 2025

Author Spotlight: EasyFlow - An Economical and Adaptable Perfusion Bioreactor for Large Blood Vessel Culture
06:44

Author Spotlight: EasyFlow - An Economical and Adaptable Perfusion Bioreactor for Large Blood Vessel Culture

Published on: July 28, 2023

4.2K

A novel flow bioreactor for in vitro microvascularization.

Eun Jung Lee1, Laura E Niklason

  • 1Department of Anesthesiology, Yale University, New Haven, CT 06520, USA.

Tissue Engineering. Part C, Methods
|February 23, 2010
PubMed
Summary
This summary is machine-generated.

Researchers developed a novel 3D in vitro perfusion system to study how fluid flow, or shear stress, impacts microvascular development. This system allows for better understanding of blood vessel formation in a controlled, biomimetic environment.

More Related Videos

Development and Characterization of In Vitro Microvessel Network and Quantitative Measurements of Endothelial [Ca2+]i and Nitric Oxide Production
09:39

Development and Characterization of In Vitro Microvessel Network and Quantitative Measurements of Endothelial [Ca2+]i and Nitric Oxide Production

Published on: May 19, 2016

9.0K
Procedure for the Development of Multi-depth Circular Cross-sectional Endothelialized Microchannels-on-a-chip
10:55

Procedure for the Development of Multi-depth Circular Cross-sectional Endothelialized Microchannels-on-a-chip

Published on: October 21, 2013

14.3K

Related Experiment Videos

Last Updated: Dec 22, 2025

Author Spotlight: EasyFlow - An Economical and Adaptable Perfusion Bioreactor for Large Blood Vessel Culture
06:44

Author Spotlight: EasyFlow - An Economical and Adaptable Perfusion Bioreactor for Large Blood Vessel Culture

Published on: July 28, 2023

4.2K
Development and Characterization of In Vitro Microvessel Network and Quantitative Measurements of Endothelial [Ca2+]i and Nitric Oxide Production
09:39

Development and Characterization of In Vitro Microvessel Network and Quantitative Measurements of Endothelial [Ca2+]i and Nitric Oxide Production

Published on: May 19, 2016

9.0K
Procedure for the Development of Multi-depth Circular Cross-sectional Endothelialized Microchannels-on-a-chip
10:55

Procedure for the Development of Multi-depth Circular Cross-sectional Endothelialized Microchannels-on-a-chip

Published on: October 21, 2013

14.3K

Area of Science:

  • Biomedical Engineering
  • Vascular Biology
  • Tissue Engineering

Background:

  • Fluid flow is crucial for in vivo vascular development and function.
  • Microvascular formation in response to flow is not well studied in 3D in vitro models.
  • Existing models lack the ability to directly investigate flow effects in a 3D environment.

Purpose of the Study:

  • To develop and validate a novel 3D in vitro perfusion system.
  • To investigate the effects of shear stress on microvascular development in a 3D collagen gel.
  • To create a controllable biomimetic environment for studying microvascularization.

Main Methods:

  • Developed a 3D in vitro perfusion system using collagen gel.
  • Suspended vascular cells and mesenchymal stem cells within the gel.
  • Perfused flow directly through the constructs to apply shear stress.
  • Cocultured endothelial cells and mesenchymal stem cells.
  • Characterized flow conditions and estimated shear stress.

Main Results:

  • Demonstrated the impact of flow on microvascular development in the 3D system.
  • Successfully created a system for applying bulk flow and estimating shear stress.
  • The system supports the development of microvasculature in response to flow.

Conclusions:

  • The novel 3D perfusion system enables direct investigation of shear stress effects on in vitro microvascular development.
  • This system provides a flexible platform for creating controllable biomimetic environments.
  • It can be adapted for various microvascularization research applications.