Self-modeling curve resolution techniques applied to comparative analysis of volatile components of Iranian saffron
Mehdi Jalali-Heravi1, Hadi Parastar, Heshmatollah Ebrahimi-Najafabadi
1Department of Chemistry, Sharif University of Technology, P.O. Box 11155-9516, Tehran, Iran. jalali@sharif.edu
Abstract:
Volatile components of saffron from different regions of Iran were extracted by ultrasonic-assisted solvent extraction (USE) and were analyzed by gas chromatography-mass spectrometry (GC-MS). Self-modeling curve resolution (SMCR) was proposed for resolving the co-eluted GC-MS peak clusters into pure chromatograms and mass spectra. Multivariate curve resolution-objective function minimization (MCR-FMIN) and multivariate curve resolution-alternating least square (MCR-ALS) were successfully used for this purpose. The accuracy of the qualitative and quantitative results was improved considerably using SMCR techniques. Comparison of the results of saffron from different regions of Iran showed that their volatile components are different from chemical components and relative percentages points of view. Safranal is the main component of all samples. In addition, 4-hydroxy-2,6,6-trimethyl-1-cyclohexene-1-carboxaldehyde (HTCC), 2(5H)-furanone, 2,4,4-trimethyl-3-carboxaldehyde-5-hydroxy-2,5-cyclohexadien-1-one and 2(3H)-furanone, dihydro-4-hydroxy were common in all samples with high percentages. The results proved that combining of SMCR techniques with USE-GC-MS produces a powerful tool for the analysis of the complex samples.
More Related Videos
06:50O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
IR Frequency Region: Fingerprint Region
The...
High-Resolution Mass Spectrometry (HRMS)
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to the...
Modeling and Similitude