Related Experiment Video
Updated: Jun 16, 2026

Semi-Automatic Graphical Tool for Measuring Coronary Artery Spatially Weighted Calcium Score from Gated Cardiac Computed Tomography Images
Published on: September 22, 2023
Scan length adjustment of CT coronary angiography using the calcium scoring scan: effect on radiation dose
Sebastian Leschka1, Chan-Hi Kim, Stephan Baumueller
1Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland. sebastian.leschka@usz.ch
Objective:
The objective of our study was to prospectively investigate the effect of adjusting the scan length of CT coronary angiography using the calcium scoring images instead of the scout view with regard to radiation dose.
Subjects And Methods:
One hundred twenty-five consecutive patients (mean age +/- SD, 62 +/- 10 years) undergoing both calcium scoring and CT coronary angiography were included in our study. The scan length of calcium scoring was planned on the scout view; the scan length of CT coronary angiography was planned on the axial images of the calcium scoring by identifying the origin of the left main artery and cardiac apex and adding 1 cm cranially and caudally. Effective radiation doses were calculated for CT coronary angiography using both scout view-derived and calcium scoring-derived scan lengths.
Results:
The scout view-derived scan length (mean +/- SD, 139 +/- 13 mm) was significantly greater than the calcium scoring-derived scan length (117 +/- 9 mm; p < 0.01). The average radiation dose was 0.8 +/- 0.3 mSv (range, 0.6-1.5 mSv) for calcium scoring and 9.0 +/- 0.6 mSv (range, 6.5-10.2 mSv) for CT coronary angiography. Using the scout view-derived scan length would have been associated with an effective radiation dose of 10.7 +/- 1.2 mSv (mean +/- SD) for CT coronary angiography, which is significantly higher than that using the calcium scoring-derived scan length (p < 0.05). The average difference between CT coronary angiography using a calcium scoring-derived scan length and that using a scout view-derived scan length was 1.7 +/- 0.9 mSv, corresponding to a radiation dose reduction of 16%. The average dose reduction when using a calcium scoring-derived instead of a scout view-derived scan length for CT coronary angiography-including the radiation dose of the calcium scoring scan-was 1.2 +/- 0.8 mSv (range, 0.1-2.7 mSv) (p < 0.05).
Conclusion:
Adjustment of the scan length of CT coronary angiography using the images from calcium scoring instead of the scout view is feasible and is associated with a 16% reduction in radiation dose of dual-source CT coronary angiography.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography