Dual Raster-Scanning Photoacoustic Small-Animal Imager for Vascular Visualization
Published on: July 15, 2020
Reconstruction of high quality photoacoustic tomography with a limited-view scanning
1Key Lab of Modern Acoustics, Ministry of Education, Nanjing University, Nanjing 210093, People's Republic of China.
Abstract:
The goal of this work is to resolve the limited-view problem of photoacoustic tomography (PAT). We report a two-loop iteration method to inverse the photoacoustic sources from the measured photoacoustic signals. PAT reconstruction with this method does not depend on the detection path. Therefore, the proposed method can provide recognizable image even when the detector only scans a small angle (about 20 degrees approximately 30 degrees). The comparison with the delay-and-sum method shows the advantage of the proposed method in reconstructing image from incomplete data.