Simulation, Fabrication and Characterization of THz Metamaterial Absorbers
Published on: December 27, 2012
Thin-film absorption coefficients by attenuated-total-reflection spectroscopy
Applied Optics
|February 23, 2010
Summary
Attenuated-total-reflection (ATR) spectroscopy effectively measures thin film absorption coefficients. This method
Area of Science:
- Spectroscopy
- Materials Science
- Optics
Background:
- Accurate measurement of thin film optical properties is crucial for device performance.
- Traditional methods may lack sensitivity for low absorption coefficients.
Purpose of the Study:
- To present the application of attenuated-total-reflection (ATR) spectroscopy for measuring thin film absorption coefficients.
- To analyze the sensitivity of ATR for low absorption scenarios using effective thickness.
Main Methods:
- Utilized attenuated-total-reflection (ATR) spectroscopy.
- Considered cases with film refractive index higher and lower than the ATR trapezoid.
- Analyzed experimental ATR data for antireflection coatings.
Main Results:
- Demonstrated ATR spectroscopy's applicability for determining thin film absorption coefficients.
- Quantified ATR sensitivity for low absorption via effective thickness.
- Compared ATR results with calorimetric data for antireflection materials.
Conclusions:
- ATR spectroscopy is a viable technique for characterizing thin film absorption.
- The effective thickness concept aids in understanding ATR sensitivity for low absorption.
- ATR data correlates well with calorimetric measurements for antireflection coatings.
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
The ATR process begins by directing a beam...
UV–Vis Spectroscopy: Beer–Lambert Law
The Beer-Lambert law describes the relationship between absorbance and concentration, which combines the principles established by scientists Johann Heinrich Lambert and August Beer. Lambert's law states that when light passes through a medium, the loss in intensity is directly proportional to the original intensity and the path length of the light. Beer's law proposed that the transmittance of a solution remains constant if the product of concentration and path length is constant. The modern...
Spectrophotometry: Introduction
Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Total Internal Reflection Fluorescence Microscopy
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
Atomic Absorption Spectroscopy: Interference
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Lab
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...