Related Experiment Video
Updated: Jun 15, 2026

Mass Spectrometric Analysis of Glycosphingolipid Antigens
Published on: April 16, 2013
Selective linkage detection of O-sialoglycan isomers by negative electrospray ionization ion trap tandem mass
Enriqueta Casal1, Rosa Lebrón-Aguilar, Francisco Javier Moreno
1Instituto de Fermentaciones Industriales, CSIC, Madrid, Spain.
Abstract:
Sialylated O-linked oligosaccharides are involved in many biological processes, such as cell-cell interactions, cell-substance adhesion, and virus-host interactions. These activities depend on their structure, which is frequently determined by tandem mass spectrometry. However, these spectra are frequently analyzer-dependent, which makes it difficult to develop widely applicable analytical methods. In order to deepen the origin of this behavior, two couples of isomers of sialylated O-linked oligosaccharides, NeuAc alpha2-3Gal beta1-3GalNAc-ol/Gal beta1-3(NeuAc alpha2-6)GalNAc-ol and NeuGc alpha2-3Gal beta1-3GalNAc-ol/Gal beta1-3(NeuGc alpha2-6)GalNAc-ol, were analyzed by liquid chromatography/negative electrospray ionization ion trap tandem mass spectrometry (LC/ESI(-)-MS(n)) using both an ion trap and a triple quadrupole mass spectrometer. Results clearly showed that while ions obtained in the triple quadrupole instrument fitted very well with the standard fragmentation routes, in the ion trap several intense ions could not be explained by these rules, specially a fragment at m/z 597. Furthermore, this ion was observed in the mass spectrum of those isomers that sialic acid binds to GalNAc by an alpha2-6 linkage. From the MS(3) spectrum of this ion an unexpected structure was deduced, and it led to propose alternative fragmentation pathways. Molecular mechanics calculations suggested that the found atypical route could be promoted by a hydrogen bond located only in alpha2-6-linked oligosaccharides. It has also been demonstrated that this process follows a slow kinetic, explaining why it cannot be observed using an ion beam-type mass analyzer. In conclusion, ion traps seem to be more appropriate than triple quadrupoles to develop a reliable analytical method to distinguish between isomeric O-linked glycans.
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Tandem Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
MALDI-TOF Mass Spectrometry
